Service Specifications: Cme1002R - Scotsman CME1002R User Manual

Scotsman cme1002r ice machine: user guide
Table of Contents

Advertisement

SERVICE SPECIFICATIONS: CME1002R

The following numbers may be used as a
guideline. There will be some variation from unit to
unit. Numbers = (Condenser/Cabinet/Water).
Typical Cycle Time
2
Harvest Time (2
min. standard) 3
3
Typical Freeze Cycle Low Side
Pressure (end of cycle)
Typical Freeze Cycle Discharge
Pressure (end of cycle)
Typical Harvest Cycle Low Side
Pressure (peak)
Typical Harvest Cycle Discharge
Pressure (min)
Typical Total Amps
5 minutes into freeze: 9.9
End of harvest: 13.6
Refrigerant Charge
288 oz of R-404A
High Pressure Cut Out
450
Typical Harvest Ice Weight
8.2 - 8.5 lb.
Pump Down Pressure Switch
Closes at 35 PSIG
Opens at 15 PSIG
Cube Size Control
Cut In adjustable between 12.5
0/70/55
13 - 14 minutes
1
minutes needed
4
25 PSIG
210 PSIG
84 PSIG
170 PSIG
o
o
F. and 24
F.
September, 1994
Page 19
CME865R & CME1002R
90/90/70
14 - 15 minutes
2 minutes
24 PSIG
240 PSIG
100 PSIG
190 PSIG
120/110/100
25 - 26 minutes
2 minutes
33 PSIG
350 PSIG
150 PSIG
270 PSIG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cme865r

Table of Contents