REMOVAL AND REPLACEMENT

Cube Size Control
To remove the cube size control:
1. Remove front panel.
2. Remove cover from control box.
3. Trace capillary tube, from the cube size control
to the refrigerant suction line.
4. Remove the coiled capillary tube bulb from the
tube well on the suction line.
5. Remove electrical leads from the cube size
control.
6. Remove screws and the cube size control. To
replace the cube size control, reverse the removal
procedure. Be certain to re-insulate the cube size
control bulb.
Water Distributor Tubes And Manifold Tubes
To remove the water distributor tube and manifold
tube:
1. Pull out to unsnap catches and remove the front
panel.
2. Remove the evaporator cover.
3. Slide the water distributor tube to the front about
1/8-inch along the top of the evaporator plate, until
the water distributor tube can be unsnapped from
the flexible notch and lifted upward to the right
side.
4. Unsnap and disconnect water distributor tubes
from the water manifold section. To replace the
water distributor tubes and manifold tubes, reverse
the removal procedure.
BE SURE the notches in the water manifold tubes
properly engage the alignment keys in the tee. BE
SURE the water distributor tube is securely
fastened at the notch at both sides of the
evaporator plate.
Check identical attachment for the left water
distributor tube and notch; also, that the
distributor/manifold connections at the top center
of each evaporator plate is snug against the top of
the plate.
Disconnect electrical
power before beginning.
October, 1994
CME855A & CME1000A
Inlet Water Solenoid Valve Assembly
To remove the inlet water solenoid valve assembly:
1. Shut OFF water supply to machine.
ELECTRICAL CORD
CONNECTION
INLET
FITTING
OUTLET
REMOVAL OF THE INLET WATER VALVE
2. Loosen and remove outlet water line from the
inlet water solenoid valve assembly.
3. Remove screws and pull the water solenoid
valve out to gain access.
4. Pull electrical cord connection from solenoid coil
terminals.
4. Remove inlet water fitting from the water
solenoid valve. To replace the inlet water valve
assembly, reverse the removal procedures.