Carrier Omnizone 50BV020-064 Installation, Start-Up, Service And Controls Operation And Troubleshooting page 38

Water-cooled indoor self-contained systems
Table of Contents

Advertisement

®
BACnet
UC Open XP
24VAC, 50-60 Hz
20VA, 0.83A
24VAC Step Down
Use Copper
Conductors Only
INPUT
Transformer
POWER
24VAC
Gnd
T1
Off
1
Power
On
Batt
-
CR2032
Port 2b*
Rnet
Local
Rnet
Access
Gnd
Gnd
Rnet+
Rnet +
Rnet-
Rnet -
+12V
Sense
+12V
Run
10's
Module
Address
1's
Error
Unused
5
6
7
8
Full Half
Duplex
EIA- EIA-
485
232
BT485
Port 2a
TO BACnet
Port 2a
MS/TP
2w 4w
232
NETWORK
Net+
Tx+
Tx
Net-
Tx-
Rx
n/c
Rx+
DTR
n/c
Rx-
DCD
Signal Ground
Tx
BT485
Port 1
Rx
Net +
Port 1
Net -
ARC156
Only
Gnd
STANDARD COMPONENTS:
EWTS - ENTERING WATER TEMPERATURE SENSOR
LWTS - LEAVING WATER TEMPERATURE SENSOR
MRV - MODULATION REHEAT VALVE
RAT - RETURN AIR TEMPERATURE SENSOR(S)
SAT - SUPPLY AIR TEMPERATURE SENSOR
BM1 - BLOWER MOTOR 1
OPTIONAL COMPONENTS:
[ ] BM2 - BLOWER MOTOR 2
[ ] CSS - COMPRESSOR STATUS SWITCHES
[ ] DSS - DUCT STATIC SENSOR
[ ] IEM - INPUT EXPANSION MODULE(S)
[ ] IN4 - CO2 SENSOR
[ ] IN5 - RELATIVE HUMIDITY SENSOR
TERMINATION DETAIL
13
RH AND C02 SENSORS
TO 24VAC CHECK
SENSOR SPECS FOR
SUPPLY VOLTAGE
INFORMATION
IN 1 AND 2
SIGNAL
IN5
COM
Gnd
IN4
SIGNAL
Gnd
COM
TERMINATION DETAIL
MODULATING RE-HEAT VALVES
AO2
Gnd
Fig. 34 — 50BVJ/W SCU VAV Open DDC Wiring Diagram
Optional - Occupancy Override
Digital Input
Universal
Input
0-10V
RTD
Therm
Dry
0-20mA
Mode
(OPN-UCXP)
Select
Even Odd
Gnd
20
20
UI-12
19
19
+
UI-11
+
18
18
Gnd
17
17
UI-10
+
16
16
UI-09
+
15
15
Gnd
14
14
UI-08
+
13
13
UI-07
12
12
+
11
11
Gnd
UI-06
+
10
10
UI-05
+
9
9
8
8
Gnd
UI-04
+
7
7
UI-03
+
6
6
Gnd
5
5
UI-02
+
4
4
Pulse Count Ability
UI-01
+
3
3
Aux Pwr Out
Gnd
2
2
Aux
Pwr Out
1
1
+24V
+5V
Gnd
12
12
AO-6
+
11
11
Gnd
10
10
AO-5
+
9
9
Gnd 8
8
AO-4
+
7
7
Gnd
6
6
AO-3
+
5
5
AO Mode Select
Gnd
4
4
AO-2
20mA
10V
+
3
3
YEL
Gnd
2
2
AO-1
20mA
10V
+
1
1
RED
Gnd
Tx
Xnet
Baud
Remote
Xnet -
Rate
Expansion
Xnet +
Rx
Switches
20
Network
20
(0 = off, 1 = on)
Unused
Protocol
19
8 7 6 5
19
MSTP (m)
0 0 0 0
18
18
MSTP (s)
0 0 0 1
BO-6
PTP
0 0 1 0
17
17
Tx
N2
®
0 0 1 1
16
16
®
15
Modbus
0 1 0 0
15
BO-5
14
SLTA
1 1 0 1
14
Rx
*PlugIn
1 1 1 0
13
13
*Ethernet
1 1 1 1
PURPLE
12
12
BO-4
11
11
10
10
9
BROWN
9
BO-3
8
8
Open Energy
Management Equipment
7
7
6
6
BO-2
5
R
5
4
4
88FO
GREEN
3
3
E143900
2
TYPE: 002108
BO-1
2
1
1
BO Rating 5A @ 250VAC
Made in USA
TO 24 VAC R&C
OF UNIT XFMR
RH
CO2
AO2
Gnd
7
7
DSS
FHP P/N
8-733-940-957
641-264
641-264
0-10 VDC
COM
1" STRAP-ON SENSOR
Ω
1" STRAP-ON SENSOR
10K
@77°F Type II Thermistor
Ω
10K
@77°F Type II Thermistor
WATER PIPE
EWTS
BLOWER HOUSING
FHP P/N 8-733-815-707
SAT
FHP P/N 8-733-815-707
2
OR
12" DUCT MOUNTED
IN5
Ω
10K
@77°F Type II Thermistor
13
SUPPLY AIR DUCT
IN4
FHP P/N T111-641-258
LWTS
1" STRAP-ON SENSOR
Ω
10K
@77°F Type II Thermistor
WATER PIPE
FHP P/N 8-733-815-707
DAMPER
MOTOR
T1
11
T2
-
2-10 V
AUX HEAT
-
12
WHT
0-10 V
BLK
BLK
WHT
8
9
TO Xnet PORT
ON OPN-UCXPIO
CONTROLLER
6
13
4
CONTROLLER IS POWERED BY DEDICATED TRANSFORMER
1
SINGLE SUPPLY AIR TEMPERATURE SENSOR FIELD
TERMINATED @ UI06. PROBE SENSOR PROVIDED FOR DUCT
2
MOUNTED APPLICATIONS (FIELD INSTALLED), STRAP-ON
SENSOR PROVIDED FOR BLOWER HOUSING MOUNTED
APPLICATIONS (FACTORY INSTALLED)
RETURN OR MIXED AIR TEMPERATURE CONTROL SENSORS
3
WIRED AS SHOWN AND FIELD TERMINATED @ UI08
TRANSFORMERS COMMON TERMINALS ARE
4
TIED TOGETHER
2ND VFD PRESENT ON 40 TON THROUGH 60 TON
5
CAPACITY ONLY.
Y3 & Y4 SIGNALS PRESENT ON 4STG UNITS ONLY
6
CSS3, CSS4 AND IEM2 PRESENT ON 4STG UNITS ONLY
7
8
FOR 4 STAGE APPLICATION, P1/P2 INTERLOCK OF BLOWER
MOTOR 2 IN SERIES WITH DI1 ON SECOND VFD
P1 & P2 INTERLOCKS OF THE BLOWER MOTOR(S) MUST BE
9
CONNECTED WITH TERMINALS 10 & 16 OF EACH VFD TO
ENABLE THE SAFETY INTERLOCK OF THE VFD AND TO
PROTECT THE MOTOR (S) FROM THERMAL DAMAGE,
TERMINALS 11 & 12 MUST ALSO BE CONNECTED TOGETHER
10
X5 AND X4 TERMINALS ARE FOUND ON ABB ACH580 VFD'S
ONLY.
OPTIONAL FIELD SUPPLIED MODULATING FRESH AIR
11
DAMPER.
OPTIONAL FIELD SUPPLIED AUXILIARY HEAT.
12
O SIGNAL WILL NOT BE PRESENT ON COOLING ONLY
13
UNITS.
DENOTES FIELD TERMINATED COMPONENTS
DENOTES STANDARD WIRING
DENOTES OPTIONAL WIRING
38
7
12" DUCT MOUNTED
3
Ω
10K
@77°F Type II Thermistors
RETURN AIR DUCT
FHP P/N T111-641-258
ABB VFD
ABB VFD
5
TERMINAL CONNECTIONS
TERMINAL CONNECTIONS
TERMINATION DETAILS
TERMINATION DETAILS
RED
RED
YEL
YEL
RED
YEL
RED
BRW
8
RED
BRW
10
10