Section 4 − Specifications; Features And Benefits; Arc Controls; Serial Number And Rating Label Location - Miller ArcReach Australia Dimension 650 Owner's Manual

Table of Contents

Advertisement

4-1. Features And Benefits

LVCt Line Voltage Compensation is circuitry that keeps the power source output constant regardless of input power fluctuation.
Wind Tunnel Technologyt circulates air over components that require cooling, not over electronic circuitry, which reduces contaminants and im-
proves reliability in harsh welding environments.
Fan-On-Demandt cooling system operates only when needed, reducing noise, energy use and the amount of contaminants pulled through the ma-
chine.
Thermal Overload Protection automatically shuts down the unit, only when necessary to prevent damage to internal components if the duty cycle
is exceeded or air flow and cooling are restricted (see Section 4-9).
Auto Remote Sense enables the unit to automatically sense the connection of a remote control. Operation of the remote control is dependent on the
Mode Switch Setting (see Section 6-2).
Lift-Arct TIG starts provide a contamination free weld without the use of high frequency (see Section 7-3).
Adaptive Hot Startt for Stick increases the output amperage at the start of a weld to eliminate electrode sticking (see Sections 9-2 and 9-3).

4-2. Arc Controls

Arc Control in Stick Modes allows the arc characteristics, soft versus stiff, to be changed for specific applications and electrodes (see Section 9-2).
Arc Control in Wire Modes influences the arc stiffness, bead width and appearance, and puddle fluidity (see Sections 8-2 and 8-3).

4-3. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.

4-4. Software Licensing Agreement

The End User License Agreement and any third-party notices and terms and conditions pertaining to third-party software can be found at
https://www.millerwelds.com/eula

4-5. Information About Default Weld Parameters And Settings

NOTICE − Each welding application is unique. Although certain Miller Electric products are designed to determine and default to certain typical welding
parameters and settings based upon specific and relatively limited application variables input by the end user, such default settings are for reference
purposes only; and final weld results can be affected by other variables and application-specific circumstances. The appropriateness of all parameters
and settings should be evaluated and modified by the end user as necessary based upon application-specific requirements. The end user is solely
responsible for selection and coordination of appropriate equipment, adoption or adjustment of default weld parameters and settings, and ultimate
quality and durability of all resultant welds. Miller Electric expressly disclaims any and all implied warranties including any implied warranty of fitness
for a particular purpose.

4-6. Unit Specifications

.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-7 and 5-8 for information on con-
necting input power.
.
This equipment will deliver rated output at an ambient air temperature up to 1045F (405C).
A. Input Voltage And Current At Rated Output
Process
GTAW (Lift-Arc TIG)
GTAW (TIG)
SMAW (Stick)
GMAW/FCAW (Gas)
FCAW-S (No Gas)
SAW (Subarc)
CAC-A (Gouge)
Idle (Fan Off)
Idle (Fan On)
OM-287308 Page 12
.
A complete Parts List is available at www.MillerWelds.com
SECTION 4 − SPECIFICATIONS
and are incorporated by reference herein.
Output Ratings
Current
Voltage
(Amperes)
(DC)
650
34
750
34
815
34
650
44
750
44
650
44
750
44
815
44
N/A
Amperes Input At Rated
Output (50 Hz)
Duty Cycle
380 VAC
(%)
100
39.1
60
45.3
25
49.4
100
49.9
60
57.9
100
49.9
60
57.9
25
63.5
1.00
1.07
Input Power
(50 Hz Three Phase)
400 VAC
KW
37.4
24.2
43.2
28.2
46.9
30.6
47.4
30.9
55.0
35.8
47.4
30.9
55.0
35.8
60.2
39.1
1.61
0.084
1.70
0.183
KVA
25.8
29.8
32.5
32.8
38.2
32.8
38.2
41.8
1.12
1.17

Advertisement

Table of Contents
loading

Table of Contents