Download Print this page

KEPCO RAX 3.3-10K Instruction Manual

50 watt single output switching power supplies

Advertisement

Quick Links

I N S T R U C T I O N M A N U A L
KEPCO
I — INTRODUCTION
SCOPE OF MANUAL. This instruction manual covers the installation and operation of the Kepco RAX 50W Series of Switching
Power Supplies. For service information, please refer to the Service Manual for the RAX 50W Series, which can be purchased
either from your Kepco Representative, or by writing directly to: Kepco Inc. 131-38 Sanford Avenue, Flushing, New York 11352,
U.S.A. When ordering a Service Manual, please state Model Designation and Serial Number of your RAX power supply.
This information can be found on the nameplate of the unit.
DESCRIPTION. The Kepco RAX 50W Series consists of seven models of switching power supplies, with a single output as
shown in Table 1. Units may be operated with either 115V a-c or 230V a-c 47-440Hz input. They will also operate on 240V to
370V d-c input. The RAX 50W Series employs a light weight ferrite core with 140 KHz switching frequency. Regulation is pro-
vided by pulse width modulation. A FET power stage, operating in the forward conversion mode provides a smooth isolated d-c
output. A triac "soft-start" circuit prevents excessive turn-on current surge. Overvoltage protection and optically isolated remote
TTL on-off control is provided. Current limiting with automatic recovery from short circuit is featured. Units are enclosed in a
wrap-around aluminum case with an LED "output present" light visible on the terminal side of the case.
Table 1 contains specifications and operating limits of individual RAX 50W Series models. Section II (following) contains specifi-
cations and operating limits common to all RAX 50W Series Models.
II — SPECIFICATIONS
The following specifications are at nominal input voltages at 25°C unless otherwise specified.
MODEL
OUTPUT VOLTS, d-c
ADJUSTMENT RANGE
MAXIMUM
50° C amb.
OUTPUT
60° C amb.
RATINGS
(AMPS,
71° C amb.
WATTS)
(1)
CURRENT LIMIT (AMPS)
OVP RANGE (VOLTS)
source (typ)
source (max)
RIPPLE
AND
switching (typ)
(2)
NOISE
(mV p-p)
switching (max)
spike noise
(3)
(max)
(1)
Change of current setting with the specified variations for operating temperatures and source input voltage is within ±10% of the rated values.
(2)
Source component 2x source frequency, and switching component approximately 140KHz.
(3)
Measured with a 50 MHz bandwidth.
INPUT VOLTAGE: (Jumper selectable, see Section III, FIG. 3):
120V a-c nominal, range: 85 -132V a-c
220-240V a-c nominal, range: 170 -264V a-c
320V d-c nominal, range: 240 -370V d-c
For d-c input the jumper is placed in the 230V position.
INPUT SOURCE FREQUENCY:
Nominal 50/60 Hz; Range 47-440 Hz. (At 400 Hz the leakage current exceeds the VDE safety specification limit.)
KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102
©2017, KEPCO, INC
Data subject to change without notice
An ISO 9001 Company.
50 WATT SINGLE OUTPUT
SWITCHING POWER SUPPLIES
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RAX 50W SERIES
RAX 3.3-10K
RAX 5-10K
3.3V
5V
1.8 - 3.6V
4.0 - 5.5V
10.0A/33W
10.0A/50W
7.0A/23.1W
7.0A/35W
4.0A/13.2W
4.0A/20W
10.5 -11.0
10.5 -11.0
3.9 - 4.8
6.0 - 6.9
5
5
10
10
25
25
40
40
100
100
http://www.kepcopower.com   email: hq@kepcopower.com
RAX 12-4.2K
RAX 15-3.4K
12V
15V
8.4 - 13.2V
12.0 - 16.5V
4.2A/50.4W
3.4A/51W
2.9A/35.3W
2.4A/35.7W
1.7A/20.1W
1.4A/20.4W
4.5 - 4.8
3.6 - 3.9
13.7 - 15.7
17.0 - 19.5
15
15
30
30
25
25
50
50
170
200
228-1225 REV 4
RAX
CAUTION: UNIT IS SET
TO 115V AC OPERATION
RAX 24-2.1K
RAX28-1.8K
24V
28V
16.8 - 26.4V
19.6 -30.8V
2.1A/50.4W
1.8A/50.4W
1.5A/35.3W
1.3A/35.3W
0.8A/20.1W
0.72A/20.2W
2.3 - 2.5
2.0 - 2.2
27.0 - 30.5
32.0 - 35.0
25
30
40
60
25
25
60
60
290
330
RAX 48-1K
48V
32.6 - 52.8V
1.0A/48W
0.7A/33.6W
0.4A/19.2W
1.1 - 1.3
55.0 - 63.0
35
90
25
60
530
1

Advertisement

loading

Summary of Contents for KEPCO RAX 3.3-10K

  • Page 1 I — INTRODUCTION SCOPE OF MANUAL. This instruction manual covers the installation and operation of the Kepco RAX 50W Series of Switching Power Supplies. For service information, please refer to the Service Manual for the RAX 50W Series, which can be purchased either from your Kepco Representative, or by writing directly to: Kepco Inc.
  • Page 2 0.75mA max at 240V d-c (U.L./VDE Method) VIBRATION: Three Axes: 5-10 Hz., 10 mm amplitude 10-55 Hz., 2g KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 228-1225 REV 4 061217...
  • Page 3 IEC 950 Safety Standards. RAX are CE marked per the Low Voltage Directive (LVD), EN60950. [The standards do not apply with DC input operation]. REMOTE ERROR SENSING: RAX 3.3-10K and 5-10K models, up to 0.25V per load wire. All other models, up to 0.4V per load wire. The power supply is factory set with links in place.
  • Page 4 KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 228-1225 REV 4 061217...

This manual is also suitable for:

Rax 5-10kRax 12-4.2kRax15-3.4kRax 24-2.1kRax28-1.8kRax 48-1k