Download Print this page
Milwaukee CD97 User Manual

Milwaukee CD97 User Manual

Digital low range tds pen
Hide thumbs Also See for CD97:

Advertisement

Quick Links

SPECIFICATIONS
RANGE
0 to 999 ppm
RESOLUTION
1 ppm
ACCURACY
±10 ppm
(@20°C)
TYPICAL
± 1 % Full Scale
EMC DEVIATION
TEMPERATURE
Automatic from
COMPENSATION
5 to 50ºC
5 to 50°C
ENVIRONMENT
95 % RH max.
BATTERY TYPE
4 x 1.5V alkaline
approximately
BATTERY LIFE
300 hours of use
DIMENSIONS
150 x 30 x 24 mm
WEIGHT
85 g
OPTIONAL ACCESSORIES
MA9300
1.5V battery (10 pcs.)
Calibration Screwdrivers
MA9701
(20 pcs)
Calibration 20 mL sachet
M10080B
800 ppm solution
(25 pcs.)
Milwaukee Instruments reserves the
right to make improvements in design,
construction and appearance of its
products without advance notice.
CERTIFICATION
Milwaukee
Instruments
conform to the CE European
Directives.
Disposal of Electrical &
Electronic Equipment. Do
not treat this product as household
waste. Hand it over to the appropriate
collection point for the recycling of
electrical and electronic equipment.
Disposal
of
waste
batteries. This product
contains batteries. Do not
dispose of them with other household
waste. Hand them over to the appropriate
collection point for recycling.
Please note: proper product and
battery disposal prevents potential
negative consequences for human
health and the environment. For
detailed information, contact your local
household waste disposal service or go to
www.milwaukeeinstruments.com (USA
& CAN) or www.milwaukeeinst.com.
WARRANTY
This instrument is warranted against
defects in materials and manufacturing
for a period of 2  years from the date
of purchase. Probe is warranted for
6  months. This warranty is limited to
repair or free of charge replacement if the
instrument cannot be repaired. Damage
due to accidents, misuse, tampering
or lack of prescribed maintenance is
not covered by warranty. If service is
required, contact your local Milwaukee
Instruments Technical Service. If the
repair is not covered by the warranty, you
will be notified of the charges incurred.
When shipping any instrument, make
sure it is properly packaged for complete
protection.
ISTCD97 11/20
USER MANUAL
Low Range TDS Pen
Pacific Sensor Technologies Pty Ltd
Unit 4, 3 Neutron Place Rowville, VIC 3178 Australia
1300 662 720 | sales@pacificsensortech.com.au
SATISFACTION
GUARANTEED
CD97
Digital
CD97
888
Distributor in Australia
www.pacificsensortech.com.au

Advertisement

loading
Need help?

Need help?

Do you have a question about the CD97 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Milwaukee CD97

  • Page 1 (25 pcs.) or lack of prescribed maintenance is not covered by warranty. If service is required, contact your local Milwaukee Distributor in Australia Instruments Technical Service. If the Pacific Sensor Technologies Pty Ltd repair is not covered by the warranty, you Unit 4, 3 Neutron Place Rowville, VIC 3178 Australia will be notified of the charges incurred.
  • Page 2 Stir gently and wait until the display BATTERY REPLACEMENT ON/OFF BATTERY SWITCH COMPARTMENT stabilizes. CD97 compensates for the When the CD97 cannot be switched temperature variance automatically. on or the display fades, pull out the LIQUID CD97 CALIBRATION CRYSTAL y Read the value on the display.