Control Panel - Quincy Compressor QGS 10 Instruction Book

Oil-injected rotary screw compressors
Table of Contents

Advertisement

Instruction book
• Unloader (UA), including inlet valve (IV) and unloading valve (UV).
• Loading solenoid valve (Y1).
• The controller that regulates the compressor based on the pressure settings and readings of
the pressure sensor.
Loading
As long as the working pressure is below the preset maximum, the solenoid valve is energised,
allowing control air to the unloader: the inlet valve opens completely and the unloading valve
closes completely. The compressor will run fully loaded (100% output).
Anticipated restart algorithm:
The unit stops loaded, because the set 'Unload' pressure is reached. The controller will anticipate
the restart 0,2 bar before reaching the set 'Load' pressure to avoid a restarting delay. Otherwise
this may result in a restarting pressure lower than the set 'Load' pressure.
Unloading
When the working pressure reaches the maximum limit, the solenoid valve is de-energised,
venting the control air: the inlet valve closes completely and the unloading valve opens
completely. The compressor will run unloaded (0% output).
The compressors are equipped with an intelligent controller that will stop the compressor after a
variable period of unloaded operation using following control algorithm:
• At power on, in the first work cycle, the 'Unload' period is 30 seconds.
• After the first work cycle, and in all other working cycles, the 'Unload' period is calculated
following 3 rules:
a. Given a max number of 10 restarts per hour (factory setting), the total running period
per cycle ('Load' time + 'Unload' time) must be minimum 6 minutes (360s).
b. At the end of the unload period the controller checks the air consumption and decides
whether to stop the unit or restart to anticipate the air demand.
c. Motor virtual temperature calculation.
If the unit is restarting frequently, or is manually restarted by the operator, the controller
will extend the unload period in order to ensure proper motor cooling. This point
overrules point the standard unload period.
The compressor will automatically restart when the net pressure drops to the minimum limit.
2.6

Control panel

2920 7113 40