Ebyte E180-ZG120A User Manual page 25

Hide thumbs Also See for E180-ZG120A:
Table of Contents

Advertisement

E18 V1.0 ZigBee Ad Hoc Network Module
Chengdu Ebyte Electronic Technology Co., Ltd.
Sample URL: cdebyte.taobao.com
For more product information, please visit: www.cdebyte.com
Report attribute ID: 0x0004 Low power consumption level of the network access module
Attribute data type: 0x30 = enum8
Data value: 0x00
Received the ZCL asynchronous command "attribute active report (type 0x82, code 0x0A)" from other ports:
55 13 82 0A 00 C5 B9 02 16 01 06 00 00 00 D9 01 00 00 10 01 2E
55 13 82 0A 00 C5 B9 02 17 01 08 00 00 00 DA 01 00 00 20 FF EC
55 13 82 0A 00 C5 B9 03 18 01 06 00 00 00 DA 01 00 00 10 01 22
55 13 82 0A 00 C5 B9 03 19 01 08 00 00 00 DA 01 00 00 20 FF E3
55 13 82 0A 00 C5 B9 04 1A 01 06 00 00 00 DA 01 00 00 10 01 27
55 13 82 0A 00 C5 B9 04 1B 01 08 00 00 00 DA 01 00 00 20 FF E6
Parse the first asynchronous command received:
Receive port: 0 – port 1
Receive Mode: 0 - On Demand Mode
Source short address: 0xB9C5
Source port: 0x02
Frame number: 0x16
Command direction: 0x01 – Server To Client
Cluster ID: 0x0006
Manufacturer code: 0x0000
Signal strength: 0xD9 = -39dbm
Total number of reported attributes: 0x01
Report attribute ID: 0x0000 PWM output switch status
Attribute data type: 0x10 = bool
Data value: 0x01 PWM output on
Parse the second asynchronous command received:
Receive port: 0 – port 1
Receive Mode: 0 - On Demand Mode
Source short address: 0xB9C5
Source port: 0x02
Frame number: 0x17
Command direction: 0x01 – Server To Client
Cluster ID: 0x0008
Manufacturer code: 0x0000
Signal Strength: 0xDA = -38dbm
Total number of reported attributes: 0x01
Report attribute ID: 0x0000 PWM output brightness
Attribute data type: 0x20 = uint8
Data value: 0xFF PWM output duty cycle is 255/255, i.e. 100%.
Step 2: Read the properties of the incoming node
The port 1 of the network access node supports cluster ID=0x0000, and there are attributes related to the node's
☆.
identity information under this cluster.
Send ZCL command "Read Device Properties (Type 0x02, Code 0x00)"
55 1F 02 00 00 C5 B9 01 A1 00 00 00 00 00 00 08 00 00 01 00 02 00 03 00 04 00 05 00 06 00 07 00 D6
Parse the send command:
Because professional, so choose!
Wireless application experts such as wireless transparent transmission,
WiFi, Bluetooth, Zigbee, PKE, digital radio, etc.
Page 1 of 40
The copyright and the final interpretation right of the product belong to Chengdu Ebyte
Electronic Technology Co., Ltd.

Advertisement

Table of Contents
loading

This manual is also suitable for:

E180-zg120b

Table of Contents