E18 V1.0 ZigBee Ad Hoc Network Module
Chengdu Ebyte Electronic Technology Co., Ltd.
Sample URL: cdebyte.taobao.com
For more product information, please visit: www.cdebyte.com
Step 6: Set the binding of the attribute report of the network access node
.Port 1 has input cluster 0xFC08, and port 2, port 3, and port 4 have input cluster 0x0006 and 0x0008. Use the
network management command "set node constant connection binding" to bind it to the serial port control port
(port 1) of the coordinator.
Send the network management command "Set node constant connection binding (type 0x01, code 0x21)":
55 19 01 21 C5 B9 01 C1 5E CA FE FF 5F 32 50 08 FC 01 6E 93 50 FE FF 14 2E 84 D3
Parse the send command
Target short address: 0xB9C5
Source virtual SN: 01 C1 5E CA FE FF 5F 32 50, the virtual SN of port 1 of the network access node
Cluster ID: 0xFC08, Ebyte serial port transparent transmission function cluster
Target virtual SN: 01 6E 93 50 FE FF 14 2E 84, the coordinator's serial port virtual SN
received feedback on the order
55 05 01 21 00 08 28
Received asynchronous command "set node ALWAYS binding response (type 0x01, code 0x21)":
55 07 81 21 C5 B9 08 00 D4
Parse asynchronous response commands
The other party's short address: 0xB9C5
Command number: 0x08
Execution result: 0x00 - binding succeeded
Received asynchronous command "Send Acknowledge" :
55 7 8F 01 C5 B9 08 00 FA
☆.When setting up the binding, it also happened that the response command and the sending acknowledgment
were reversed. According to this format, continue to bind the cluster 0x0006 and cluster 0x0008 of port 2, port 3,
and port 4 of the inbound node.

4.1.3 Control access nodes

Step 1: Receive the attribute report of the network access node
☆.The attribute report of the node can be used as a heartbeat packet
Received the ZCL asynchronous command "property active reporting (type 0x82, code 0x0A)":
55 13 82 0A 00 C5 B9 01 07 01 08 FC 00 20 DF 01 04 00 30 00 CD
Parse the received asynchronous command:
Receive port: 0 - the module's default port (port 1) to receive the message
Receive mode: 0 - On-demand mode, can't judge whether the signal strength is valid or not
Source short address: 0xB9C5
Source port: 0x01
Frame number: 0x07
Command direction: 0x01 – Server To Client
Cluster ID: 0xFC08
Manufacturer code: 0x2000
Signal Strength: 0xDF = -33dbm
Total number of reported attributes: 0x01
Because professional, so choose!
Wireless application experts such as wireless transparent transmission,
WiFi, Bluetooth, Zigbee, PKE, digital radio, etc.
Page 1 of 40
The copyright and the final interpretation right of the product belong to Chengdu Ebyte
Electronic Technology Co., Ltd.

Advertisement

Table of Contents
loading

This manual is also suitable for:

E180-zg120b

Table of Contents