Manual Calibration Function; Deaeration Function; Commission Set Up (Gas) - Changing The Type Of Gas - ECR International Utica Boilers MAH-125 Installation, Operation And Maintenance Manual

Condensing wall mounted gas fired boiler
Table of Contents

Advertisement

9.9 Manual Calibration Function:

Manual Calibration phase starts at the end of the Automatic
Calibration.
The Display shows the boiler power and adjustment of the
CO2 value (parameter setting) during Manual Calibration
sequence.
The process begins at minimum power.
A. After Automatic Calibration sequence with
flashing together on the display, you can adjust
minimum power combustion by pressing
CO
, and
to raise % CO
2
B. When minimum power combustion is in the specified
range, press
and then
C. Press
to adjust ignition power combustion. Press
to lower % CO
, and
2
D. When ignition power combustion is in the specified
range, press
and then
E. Press
to adjust maximum power combustion. Press
to lower % CO
, and
2
F. When maximum power combustion is in the specified
range, press
to exit Manual Calibration Function.
IMPORTANT INFORMATION
A. If venting or gas recognition function is interrupted
by power blackout, start function again when power is
restored. Press
and
time for at least 6 seconds.
B. If display shows fault E118 (low pressure in hydraulic
circuit) during venting function, open filling tap on
appliance and restore correct pressure.
C. If gas recognition function is interrupted due
to fault (e.g.: E133 no gas) press
reset. Then press
6 seconds) to restart the function again.
If gas recognition function is interrupted due to
overheating, restart function by pressing and holding
down together for at least 6 seconds.
D. Combustion of this appliance has been factory controlled,
calibrated and set for operation with Gas A (Natural
Gas).
E. During Gas Type Control Function, combustion ratio will
increase for a short period of time while gas type is being
established.

9.10 Deaeration Function

Used to eliminate air inside the heating circuit when boiler
is installed or after maintenance when water is drained from
primary circuit.
Press buttons
1.
On appears on display for a few seconds, followed by
program row 312.
The electronic board will activate pump on/off cycle for
2.
10 minutes. Function will automatically stop at end of the
cycle.
To manually exit this function, press
3.
together and hold for 6 seconds.
9 - START UP PROCEDURE
to lower %
.
2
to reach ignition power.
to raise % CO
.
2
to reach maximum power.
to raise % CO
.
2
together and hold at same
to
and
(for at least
together and hold for 6 seconds.
buttons
FIGURE 9-3 - Gas Inlet Tap - Pi
PI = Gas Supply Inlet Pressure Tap
9.11 Commission Set Up (Gas) - Changing The Type
Of Gas
During the first installation boiler carries out an automatic
commissioning function.
The system is able to detect the gas type present in the
network.
Correct gas type setting, is made by pressing two buttons at
the same time, see section 9.6 Commissioning.
Change of gas type is made after the first installation:
• Change parameter P02. See section 9.7 Commissioning
and section 9.13 Parameter Settings.
• Check minimum gas pressure is suitable for selected gas:
Gas A (NG) = 3.5" (8.7 mbar)
Gas E (LPG) = 8.0" (19.9 mbar)
• Place supplied label with indication of gas type close to
the data plate of boiler replacing the original.
• Perform Automatic Calibration Function - Section 9.8.
• Manufacturer recommends
on the flue.
45
verification of CO
concentration
2
240011941 REV G, [06/30/2019]

Advertisement

Table of Contents
loading

Table of Contents