(B) Outdoor Unit - Sanyo SPW-D253G56 Service Manual

Split system air conditioner
Table of Contents

Advertisement

1-2 Major Component Specifications

(B) Outdoor Unit

MODEL No.
Source
Compressor
Model ... Code No.
Nominal output
Compressor oil
Coil resistance (at 25°C)
Refrigerant amount at shipment
Safety device
Operating temperature
Run capacitor
High pressure switch
Set pressure
Fan (Number...diameter (mm))
Fan motor
Model...Nominal output
No. of pole ... rpm (230V, High)
Coil resistance
(Ambient temperature 20°C)
Safety device
Operating temperature
Run capacitor
Heat exchanger
Coil
Rows ... fin pitch
Face area
SPW-C253G5
SPW-C253G5/M
C - R221H5V
W
2,200
cc
C - R :
0.76 , C - S
kg
R22 - 2.4
Internal/OL - D24
°C
160 ± 5 / 150 ± 10
Open
°C
87 ± 9 / 63 ± 10
Close
V, µF
2
OFF kg/cm
2
ON
kg/cm
Propeller (1...ø 460)
W
KFC6S - 91C5P...100 W
rpm
Internal type
°C
130 ± 8
Open
°C
79 ± 15
Close
VAC, µF
440 V, 5 µF
mm
2...2.0
m
2
0.616
– 17 –
1. Specifications
1. Specifications
1. Specifications
SPW-C363G5
SPW-C363G5/M
220 - 230 - 240 V / 1 phase / 50 Hz
Rotary (Hermetic)
C - R240H5W
2,400
1,350
: 2.76
C - R : 0.69 , R - S : 3.34
S - C : 2.66
R22 - 4.2
Internal type
175 ± 5
105 ± 9
400V, 40
ACB - 1TB07
+ 2.0
30
+ 0.5
24 ± 2.0
Propeller (2...ø 460)
KFC6S - 91C5P X 2
...100 W X 2
6...868
BRW – WHT
:
61.0
YEL – PNK
:
17.7
WHT – YEL
:
64.3
Internal type
130 ± 8
79 ± 15
440 V, 5 µF / 5 µF
Aluminium plate fin / Copper tube
1
6...871
2...2.0
1.08
SM830044

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents