Page 1
Amana Domestic Gas DryerTechnical Information 120 V, 60 Hz Models ALG443RAC PALG443RAC ALG443RAW PALG443RAW ALG443RCW PALG443RCW ALG443RAW PALG443RAW1 • Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.
Page 2
Component Testing Information WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer and shut-off gas supply before servicing, unless testing requires it. Illustration Component Test Procedure Results ° ± ° Thermostat limit Measure resistance of the following Open at 225 terminals: °...
Page 3
Component Testing Information WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer and shut-off gas supply before servicing, unless testing requires it. Illustration Component Test Procedure Results Igniter Measure resistance of the following: − Ω...
Page 4
Internal Motor Diagram and Schematic WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer and shut-off gas supply before servicing, unless testing requires it. Unplug motor wire terminal from motor before starting this test. Continuity exists between switch terminal 5 and Black wire.
Page 5
Internal Motor Diagram and Schematic WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer and shut-off gas supply before servicing, unless testing requires it. MAIN START ORANGE CUSTOMER CIRCUIT PUSH TO START LINE SWITCH SHOWN IN START POSITION R.S.P.C.
Page 6
Wiring Diagram and Schematic WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer and shut-off gas supply before servicing, unless testing requires it. THIS MACHINE MANUFACTURED UNDER ONE OR MORE OF THE WARNING FOLLOWING PATENTS: Failure to install, maintain, and/or operate this UNITED STATES NO: 5,113,562 machine according to manufacturer's...
Page 7
Wiring Diagram and Schematic WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer and shut-off gas supply before servicing, unless testing requires it. September 2002 16021967 Rev. 0 (This technical sheet replaces RT3210004 Rev. 1.)