MODELS
BEV unit
BEVN32AV1
BEVN50AV1
BEVN125AV1
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.
LIRE SOIGNEUSEMENT CES INSTRUCTIONS AVANT L'INSTALLATION.
CONSERVER CE MANUEL A PORTEE DE MAIN POUR REFERENCE ULTERIEURE.
LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR.
GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER ALGUNA
DUDA.
PRIMA DELL'INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI.
TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI.
ÄΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ ΟÄΗΓΙΕΣ ΠΡΙΝ ΑΠΟ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΕΧΕΤΕ ΑΥΤΟ ΤΟ
ΕΓΧΕΙΡΙÄΙΟ ΕΥΚΑΙΡΟ ΓΙΑ ΝΑ ΤΟ ΣΥΜΒΟΥΛΕΥΕΣΤΕ ΣΤΟ ΜΕΛΛΟΝ.
LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE. BEWAAR DEZE HAN-
DLEINDING WAAR U HEM KUNT TERUGVINDEN VOOR LATERE NASLAG.
LEIA COM ATENÇÃO ESTAS INSTRUÇÕES ANTES DE REALIZAR A INSTALAÇÃO.
MANTENHA ESTE MANUAL AO SEU ALCANCE PARA FUTURAS CONSULTAS.
ПЕРЕД НАЧАЛОМ МОНТАЖА ВНИМАТЕЛЬНО ОЗНАКОМЬТЕСЬ С ДАННЫМИ
ИНСТРУКЦИЯМИ. СОХРАНИТЕ ДАННОЕ РУКОВОДСТВО В МЕСТЕ, УДОБНОМ ДЛЯ
ОБРАЩЕНИЯ В БУДУЩЕМ.
MONTAJDAN ÖNCE BU TALÝMATLARI DÝKKATLÝ BÝR BÝÇÝMDE OKUYUN.
GELECEKTE BAÞVURMAK ÜZERE BU ELKÝTABINI KOLAY ULAÞABÝLECEÐÝNÝZ BÝR YERDE
MUHAFAZA EDÝN.

INSTALLATION MANUAL

SYSTEM Air Conditioners
English
Deutsch
Français
Español
Italiano
ëëçíéêÜ
Nederlands
Portugues
óññêèé

Advertisement

Table of Contents
loading

Summary of Contents for Daikin BEVN32AV1

  • Page 1: Installation Manual

    INSTALLATION MANUAL English SYSTEM Air Conditioners Deutsch MODELS Français BEV unit BEVN32AV1 Español BEVN50AV1 BEVN125AV1 Italiano ëëçíéêÜ READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. Nederlands LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
  • Page 2 2P229632-1...
  • Page 3: Table Of Contents

    BEVN32AV1 BEVN50AV1 VRV SYSTEM Air Conditioners Installation manual BEVN125AV1 CONTENTS 1. SAFETY PRECAUTIONS....................1 2. BEFORE INSTALLATION ....................3 3. BEFORE INSTALLATION ....................4 4. SELECTING INSTALLATION SITE................4 5. PREPARATIONS BEFORE INSTALLATION ..............5 6. BEV UNIT INSTALLATION ....................6 7. REFRIGERANT PIPING WORK ..................6 8.
  • Page 4 • Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal connections or wires. Improper connections or securing of wires may result in abnormal heat build-up or fire. • When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires so that the EL.
  • Page 5: Before Installation

    3. The indoor unit is an R744-dedicated unit. The following indoor unit models are connectable. (Do not connect other indoor unit models, or otherwise an inner piping rupture will result.) 2-2 COMBINATION Attach a BEV unit to the indoor unit. As shown in the below table. BEV unit BEVN32AV1 BEVN50AV1 BEVN125AV1 FXSN20AV1 FXSN40AV1...
  • Page 6: Before Installation

    2-4 CHECK ITEM • FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONSTRUCTION AND CHECK AFTER INSTALLATION IS FINISHED. Items to be checked after completion of work Items to be checked If not properly done, what is likely to occur Check Are the indoor and outdoor unit fixed firmly? The units may drop, vibrate or make noise.
  • Page 7: Preparations Before Installation

    〈〈Installation space〉〉 Install so that the EL. COMPO. BOX lid is facing down. EL. COMPO. BOX lid Maintenance hole 600 or more Connected to outdoor unit Connected to indoor unit Be sure to create a maintenance hole the Wire service 200 or more 200 or more size shown in the...
  • Page 8: Bev Unit Installation

    6. BEV UNIT INSTALLATION • Use only accessories and parts which are of the designated specification when installing. (1) Temporarily install the BEV unit. Washer (field supplied) • Mount the hanging fittings to hanging bolts. Secure the Nut (field supplied) hanging fittings on the top and the bottom with nuts (M8, Double nut field supplied) and washers (M8: Outside diameter size...
  • Page 9 7-3 PIPING PROTECTION During the period of installation work, perform the protection of piping according to the Table 1 in order to pre- vent the ingress of moisture, dust, and dirt. Table 1 Place Period of work Protection method At least one month Pinching Outdoors Less than one month...
  • Page 10 7-5 HEAT INSULATION WORK • After the gas leakage inspection of piping joints, refer to Fig. 3 and Fig. 4 and conduct heat insula- tion work on the joints. • Use insulation for fitting (3) to conduct the heat insulation work. (Refer to Fig. 3) The heat insulation mate- rial is provided to the liquid and gas pipes, respectively.
  • Page 11: Electric Wiring Work

    7-6 PIPING CONNECTION PROCEDURE (1) Connection example for the indoor unit • Only one indoor unit may be connected to each BEV unit. Gas piping Adjusted to fit the Outdoor unit size of the piping Indoor unit Liquid piping BEV unit connection hole on the indoor unit.
  • Page 12 (1) Electrical characteristics Units Power supply Model Voltage Min. Max. BEVN32AV1 BEVN50AV1 BEVN125AV1 MCA: Min. Circuit Amps (A); MFA: Max. Fuse Amps (A) NOTES • The above Table of Electrical characteristics refers to the BEV unit only. • See the technical documents for other details.
  • Page 13 PRECAUTIONS Use ring-type crimp-style terminals for connecting wires to Ring-type crimp style terminal the power supply terminal board. If unavailable, observe the following points when wiring. Electric wire • Do not coat stranded wires with solder. Attach insulation sleeve • Do not connect wires of different gauge to the same power supply terminal.
  • Page 14: Connection Of Wiring

    8-3 CONNECTION OF WIRING • Perform wiring connections after completion of refrigerant piping work. • Check that all the power supply lines are shut off. • Loosen the two screws of the EL. COMPO. BOX, remove the lid, and connect each wire as shown in Fig. 6. •...
  • Page 15: Test Operation

    • Transmission wiring Remove the EL. COMPO. BOX lid, and connect the transmission wires to the transmission wiring terminals (F1 and F2 on the indoor side and F1 and F2 on the outdoor side). In that case, pull the wires into the equip- ment through the wiring through hole, and bundle and fix the wires securely with the accessory clamp (1).