TCX1000 Inline Amplifier Hardware Guide
Modified: 2019-02-12
Copyright © 2019, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for Juniper TCX1000

  • Page 1 TCX1000 Inline Amplifier Hardware Guide Modified: 2019-02-12 Copyright © 2019, Juniper Networks, Inc.
  • Page 2 END USER LICENSE AGREEMENT The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at https://support.juniper.net/support/eula/.
  • Page 3: Table Of Contents

    FRU Panel ..........18 TCX1000-ILA Chassis Status LEDs ........19 TCX1000-ILA Management Panel .
  • Page 4 Initial Installation and Configuration ....... . . 43 Overview of Installing the TCX1000-ILA ....... . . 43 Unpacking and Mounting the TCX1000-ILA .
  • Page 5 Troubleshooting the TCX1000-ILA ........
  • Page 6 TCX1000-ILA Agency Approvals and Compliance Statements ....112 TCX1000-ILA Agency Approvals ........112 Compliance Statements for EMC Requirements .
  • Page 7: About The Documentation

    ® To obtain the most current version of all Juniper Networks technical documentation, see the product documentation page on the Juniper Networks website at https://www.juniper.net/documentation/ If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
  • Page 8 TCX1000 Inline Amplifier Hardware Guide Table 1: Notice Icons Icon Meaning Description Informational note Indicates important features or instructions. Caution Indicates a situation that might result in loss of data or hardware damage. Warning Alerts you to the risk of personal injury or death.
  • Page 9: Documentation Feedback

    We encourage you to provide feedback so that we can improve our documentation. You can use either of the following methods: Online feedback system—Click TechLibrary Feedback, on the lower right of any page on the Juniper Networks TechLibrary site, and do one of the following: Copyright © 2019, Juniper Networks, Inc.
  • Page 10: Requesting Technical Support

    7 days a week, 365 days a year. Self-Help Online Tools and Resources For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features: Find CSC offerings: https://www.juniper.net/customers/support/...
  • Page 11: Creating A Service Request With Jtac

    About the Documentation Join and participate in the Juniper Networks Community Forum: https://www.juniper.net/company/communities/ Create a service request online: https://myjuniper.juniper.net To verify service entitlement by product serial number, use our Serial Number Entitlement (SNE) Tool: https://entitlementsearch.juniper.net/entitlementsearch/ Creating a Service Request with JTAC You can create a service request with JTAC on the Web or by telephone.
  • Page 12 TCX1000 Inline Amplifier Hardware Guide Copyright © 2019, Juniper Networks, Inc.
  • Page 13: Overview

    TCX Series Optical Transport System Feature Guide at https://www.juniper.net/documentation/ The proNX Optical Director is required for the proper operation of the TCX1000-ILA. For more information about configuring the TCX1000-ILA, see the proNX Optical Director User Guide and the proNX Optical Director Installation Guide at https://www.juniper.net/documentation/product/en_US/pronx-optical-director...
  • Page 14: Front Panel

    4— Power supplies The cooling system in the TCX1000-ILA consists of three 12.4-W fan modules. These fan modules can be hot-swapped—you do not need to power off the TCX1000-ILA or disrupt the functioning of the TCX1000-ILA to replace a fan module. The TCX1000-ILA has two 150-W power supplies, either AC or DC depending on your configuration.
  • Page 15: Tcx1000-Ila Hardware Component Overview

    TCX1000-ILA within the desired temperature thresholds, chassis alarms are raised and the TCX1000 ILA can shut down. The TCX1000-ILA ships with two power supplies that provide 1+1 redundancy. If one power supply fails or is removed, the second power supply balances the electrical load without interruption and still provides 1+1 redundancy while the failing power supply is replaced.
  • Page 16: Tcx1000-Ila Chassis

    Table 5 on page 16 lists the FRUs for the TCX1000-ILA and actions to take before removing them. Table 5: Required Actions Before Removing a FRU from the TCX1000 ILA Required Actions Before Removal Power supplies (2) Disconnect the AC power and remove the AC power cord or cable for the power supply unit.
  • Page 17: Tcx1000-Ila Chassis Description

    TCX1000-ILA Management Port LEDs on page 22 TCX1000-ILA Chassis Description The TCX1000-ILA chassis is a rigid sheet metal structure that houses all the other hardware components. The chassis measures 1.72 in. (4.36 cm) high, 9.6 in. (24.4 cm) deep, and 17.24 in. (43.8 cm) wide. The chassis can be installed in racks or cabinets.
  • Page 18: Fru Panel

    ) ports for monitoring). See Figure 5 on page The TCX1000-ILA accepts two line connections (LC): Line A and Line B and is bidirectional. It provides optical gain for the optical signal traversing the amplifier in the A-B direction, and the signal traversing the amplifier in the opposite B-A direction. Thus, it can be viewed as two amplifiers in one box.
  • Page 19: Tcx1000-Ila Chassis Status Leds

    Chapter 1: Overview The TCX1000-ILA has two 150-W power supplies, either AC or DC depending on your configuration. The power supplies need to be both AC or both DC—you cannot mix AC and DC power supplies in the same chassis. Only one power supply is required to power the device, while the second power supply provides redundancy.
  • Page 20 Green On steadily OSC signal is communicating normally. System status ( ) LED Unlit The power is off, or the TCX1000-ILA is not connected to any power source. Green On steadily The TCX1000-ILA software has booted. Green Blinking...
  • Page 21: Tcx1000-Ila Management Panel

    The TCX1000-ILA is by managed by proNX Optical Director. The proNX Optical Director, is a distributed software platform that provides optical control and management of all products in the TCX Series Optical Transport System. The proNX Optical Director also...
  • Page 22: Tcx1000-Ila Management Port Leds

    TCX1000-ILA System Overview on page 13 TCX1000-ILA Cooling System Description The cooling system in a TCX1000-ILA consists of three 12.4-W fan modules installed in the field-replaceable unit (FRU) panel and two counter-rotating fans housed in each of the power supplies.
  • Page 23: Fan Modules

    Chapter 1: Overview In the TCX1000-ILA's cooling system, cool air enters through the vents in the front panel and hot air exhausts through the fans in the FRU panel. This type of airflow is known as airflow out or front-to-back airflow. When installed, the chassis must be positioned so that the FRUs are next to the hot air exhaust.
  • Page 24: Tcx1000-Ila Power System

    ) are hot-removable and hot-insertable field-replaceable units (FRUs) that you can install without powering off the TCX1000-ILA or disrupting the functioning of the TCX1000-ILA. The TCX1000-ILA has two AC power supplies. Both the power supplies are initially installed at the factory.
  • Page 25: Tcx1000-Ila Dc Power Supply Description

    Each of the two 150-W power supplies has a single DC input. The power supply provides 12 VDC output with a standby voltage of 12 VDC. An TCX1000-ILA has twice the number of power supplies needed to power all of the components in the device, which is known as 1+1 redundancy.
  • Page 26: Tcx1000-Ila Power Supply Leds

    For more information about power system redundancy, see“TCX1000-ILA Component Redundancy” on page 15 TCX1000-ILA Power Supply LEDs Each TCX1000-ILA power supply has two LEDs on the power supply faceplate. Figure 15 on page 26 shows the location of the LEDs on an TCX1000-ILA AC power supply.
  • Page 27 DC OUT OK 2— DC IN OK Table 8 on page 27 Table 9 on page 28 to interpret the state of the power supply LEDs. Table 8: TCX1000-ILA AC Power Supply LED Name Color State Description DC OK Unlit There is no power to any of the power supplies.
  • Page 28: Tcx1000-Ila Power Consumption Specifications

    TCX1000-ILA DC input voltage range –60 –48 –44 TCX1000-ILA DC input current range 2.8 A – 4.7 A TCX1000-ILA AC Power Supply Specifications Table 11 on page 29 describes the AC power supply specifications for an TCX1000-ILA. Copyright © 2019, Juniper Networks, Inc.
  • Page 29: Tcx1000-Ila Ac Power Cord Specifications

    Code (CEC) Section 4-010(3). The cords that can be ordered for the TCX1000-ILA are in compliance. Table 12 on page 29 lists AC power cord specifications provided for each country or region. Table 12: AC Power Cord Specifications for the TCX1000-ILA Country Model Number Electrical Specification...
  • Page 30: Tcx1000-Ila Dc Power Specifications

    TCX1000 Inline Amplifier Hardware Guide Table 12: AC Power Cord Specifications for the TCX1000-ILA (continued) Country Model Number Electrical Specification Plug Type Japan CBL-GP-JX-PWR-JP 125 VAC, 12 A, 50 Hz or 60 Hz JIS 8303 and 8306 North America CBL-GP-JX-PWR-US...
  • Page 31: Dc Power Connector

    TCX1000-ILA must be adequately grounded before power is connected to ensure proper operation and to meet safety and electromagnetic interference (EMI) requirements. To ground an TCX1000-ILA, connect a grounding cable to earth ground and then attach it to the chassis grounding points.
  • Page 32 The grounding lug required is a Panduit LCD6-14BH-L or equivalent (provided). The grounding lug accommodates 14–10 AWG (2–5.3 mm²) stranded wire. The grounding cable that you provide for an TCX1000-ILA must be the same size or heavier than the input wire of each power supply. Minimum recommendations are 14–10 AWG (2–5.3 mm²) stranded wire, 60°...
  • Page 33: Site Planning, Preparation, And Specifications

    Site Planning, Preparation, and Specifications TCX1000-ILA Site Guidelines and Requirements on page 33 TCX1000-ILA Management Cable Specifications and Pinouts on page 39 TCX1000-ILA Site Guidelines and Requirements TCX1000-ILA Site Preparation Checklist on page 33 TCX1000-ILA Environmental Requirements and Specifications on page 34...
  • Page 34: Tcx1000-Ila Environmental Requirements And Specifications

    Overview of Installing the TCX1000-ILA on page 43 Unpacking and Mounting the TCX1000-ILA on page 44 TCX1000-ILA Environmental Requirements and Specifications The TCX1000-ILA must be installed in a rack or cabinet. It must be housed in a dry, clean, well-ventilated, and temperature-controlled environment. Follow these environmental guidelines: The site must be as dust-free as possible, because dust can clog air intake vents and filters, reducing the efficiency of the TCX1000-ILA cooling system.
  • Page 35: Tcx1000-Ila Clearance Requirements For Airflow And Hardware Maintenance

    See Also Overview of Installing the TCX1000-ILA on page 43 TCX1000-ILA Clearance Requirements for Airflow and Hardware Maintenance When planning the site for an TCX1000-ILA installation, you must allow sufficient clearance around the installed chassis (see Figure 17 on page 36).
  • Page 36: Tcx1000-Ila Physical Specifications

    TCX1000-ILA chassis. You must leave at least 24 in. (61 cm) both in front of and behind the TCX1000-ILA. For service personnel to remove and install hardware components, you must leave adequate space at the front and back of the TCX1000-ILA.
  • Page 37: Tcx1000-Ila Rack Requirements

    (document number EIA-310–D) published by the Electronics Components Industry Association http://www.ecianow.org/ Mounting bracket hole The holes in the mounting brackets are spaced at 1.25 in. (or 3.17 cm), so that the TCX1000-ILA spacing can be mounted in any rack that provides holes spaced at that distance.
  • Page 38: Tcx1000-Ila Cabinet Requirements

    Maintenance and Operational Safety Guidelines and Warnings on page 96 TCX1000-ILA Cabinet Requirements You can mount TCX1000-ILA models in a cabinet that contains a two-post 19-in. or four-post rack as defined in Cabinets, Racks, Panels, and Associated Equipment (document number EIA-310-E) published by the Electronics Components Industry Association http://www.ecianow.org/...
  • Page 39: Tcx1000-Ila Optical Specifications

    Cable Specifications for Console and Management Connections for the TCX1000-ILA Table 21 on page 39 lists the specifications for the cables that connect the TCX1000-ILA to a management device. Table 21: Cable Specifications for Console and Management Connections for the TCX1000-ILA Port on Device TCX1000-ILA...
  • Page 40: Management Port Connector Pinouts For The Tcx1000-Ila

    Table 23 on page 40 provides the pinout information for the RJ-45 console connector. Tje RJ-45 cable and RJ-45 to DB-9 adapter are not supplied with the TCX1000-ILA. NOTE: If your laptop or PC does not have a DB-9 male connector pin and you...
  • Page 41 Chapter 2: Site Planning, Preparation, and Specifications Table 23: Console Port Connector Pinouts for the TCX1000-ILA (continued) Signal Description TxD Output Transmit data Signal Ground Signal ground Signal Ground Signal ground RxD Input Receive data Reserved Reserved Reserved Reserved Copyright © 2019, Juniper Networks, Inc.
  • Page 42 TCX1000 Inline Amplifier Hardware Guide Copyright © 2019, Juniper Networks, Inc.
  • Page 43: Initial Installation And Configuration

    Overview of Installing the TCX1000-ILA on page 43 Unpacking and Mounting the TCX1000-ILA on page 44 Connecting the TCX1000-ILA to External Devices on page 47 Connecting the TCX1000-ILA to Power on page 50 Configuring the Software on the TCX1000-ILA on page 56...
  • Page 44: Unpacking And Mounting The Tcx1000-Ila

    TCX Series documentation. CAUTION: The TCX1000-ILA chassis is maximally protected inside the shipping carton. Do not unpack the TCX1000-ILA until you are ready to begin installation. To unpack an TCX1000-ILA: Move the shipping carton to a staging area as close to the installation site as possible, but where you have enough room to remove the system components.
  • Page 45: Mounting An Tcx1000-Ila In A Rack Or Cabinet

    Documentation Roadmap card Mounting an TCX1000-ILA in a Rack or Cabinet You can mount an TCX1000-ILA in a two-post or four-post 19-in. rack or cabinet by using the attached mounting brackets. (The remainder of this topic uses rack to mean rack or cabinet.)
  • Page 46: Mounting The Tcx1000-Ila

    NOTE: This procedure requires two persons. Do not attempt to do it alone. Mounting the TCX1000-ILA To mount the TCX1000-ILA on two posts or four posts in a rack by using the provided mounting kit (see Figure 18 on page...
  • Page 47: Connecting The Tcx1000-Ila To External Devices

    Connecting the TCX1000-ILA to the Network and External Devices on page 49 Connecting the TCX1000-ILA to a Management Ethernet Device You can monitor and manage the TCX1000-ILA by using a dedicated management channel. Use the management port to connect the TCX1000-ILA to a network for out-of-band management. NOTE: You cannot use the management port to perform the initial configuration of the TCX1000-ILA.
  • Page 48: Connecting The Tcx1000-Ila To A Management Console

    Figure 19: Connecting an TCX1000-ILA to a Network for Out-of-Band Management Connecting the TCX1000-ILA to a Management Console The TCX1000-ILA has a console port with an RJ-45 connector. Use the console port to connect the device directly to a management console, such as a laptop, or to a console server.
  • Page 49: Connecting The Tcx1000-Ila To The Network And External Devices

    For detailed information on network requirements and configuration examples on how to deploy the TCX1000-ILA, see the TCX Series Optical Transport System Feature Guide. For instructions on how to enable the OSC forwarding on the TCX1000-RDM20, see the “Performing the Initial Configuration section” in the TCX1000 Programmable ROADM Hardware Guide.
  • Page 50: Connecting The Tcx1000-Ila To Power

    For installations that require a separate grounding conductor to the chassis, use the protective earthing terminal on the TCX1000-ILA chassis to connect to the earth ground.
  • Page 51: Connecting Ac Power To An Tcx1000-Ila

    For installations that require a separate grounding conductor to the chassis, use the protective earthing terminal on the TCX1000-ILA chassis to connect to the earth ground (see Figure 22 on page 51).
  • Page 52 Figure 23 on page Figure 23: Connecting an AC Power Cord to an AC Power Supply in an TCX1000-ILA If the AC power source outlet has a power switch, set it to the off ( ) position.
  • Page 53: Connecting Dc Power To An Tcx1000-Ila

    For installations that require a separate grounding conductor to the chassis, use the protective earthing terminal on the TCX1000-ILA chassis to connect to the earth ground (see “Connecting the TCX1000-ILA to Power” on page 50).
  • Page 54 TCX1000 Inline Amplifier Hardware Guide Install the power supply in the chassis following the instructions in“Installing a Power Supply in an TCX1000-ILA” on page 65 Ensure that you have the following parts and tools available: ESD grounding strap Power cable or cables appropriate for your geographical location available to connect DC power to the TCX1000-ILA.
  • Page 55 (see Figure 24 on page 55). Insert the DC connector in the TCX1000-ILA DC power supply. Tighten the attached screws (top and bottom) on the DC power connector to apply a torque of 4.5 lb-in. (0.5 Nm). See...
  • Page 56: Configuring The Software On The Tcx1000-Ila

    (CLI). The TCX1000-ILA supports two command line modes. When you first log in to the TCX1000-ILA, you are placed into user mode. In user mode, you can issue basic commands such as ping but you do not have access to regular CLI commands. To get access to the regular CLI, you need to log in to the administrative mode from user mode.
  • Page 57 (admin) and the password (admin). Make sure your PC is on the same subnet as the TCX1000-ILA IP address. The user mode username and password are used if you are using SSH to connect to the CLI interface.
  • Page 58 TCX1000 Inline Amplifier Hardware Guide at the prompt. EDFA>login Username: WRuser Password: ********* CLI User “WRuser” default password is WRuser123 ***************************************** Please change default password!!! ***************************************** Enter new password:******** Retype new password:******** ***************************************** OK. Please remember new password!!! ***************************************** Completed! EDFA>...
  • Page 59 MGMT ) to the DCN to verify the IP address you configured. Use SSH to connect to the TCX1000-ILA and log in with the username (admin) and the configured password. Use the proNX Optical Director to provision, monitor, and activate services on the TCX1000-ILA.
  • Page 60 TCX1000 Inline Amplifier Hardware Guide Copyright © 2019, Juniper Networks, Inc.
  • Page 61: Maintaining Components

    Before removing the fan module, ensure that you have a replacement fan module available. Before you remove a fan module from an TCX1000-ILA, ensure that you have taken the necessary precautions to prevent electrostatic discharge (ESD) damage (see “Prevention...
  • Page 62: Installing A Fan Module In An Tcx1000-Ila

    CLI command to view the message. show alarm Installing a Fan Module in an TCX1000-ILA The fan modules in an TCX1000-ILA are hot-removable and hot-insertable field-replaceable units (FRUs)—you can remove and replace them without powering off the TCX1000-ILA or disrupting routing functions.
  • Page 63: Maintaining The Tcx1000-Ila Power System

    ESD points on the chassis. Taking care not to touch the connectors, remove the fan module from its bag. Align the module with the open slot on the FRU end of the TCX1000-ILA and slide it in until it is fully seated.
  • Page 64: Removing A Power Supply From An Tcx1000-Ila

    Before removing the power supply, ensure that you have a replacement power supply available or install a blank cover. Before you remove a power supply from an TCX1000-ILA, ensure that you have taken the necessary precautions to prevent electrostatic discharge (ESD) damage (see “Prevention of Electrostatic Discharge Damage”...
  • Page 65: Installing A Power Supply In An Tcx1000-Ila

    Take care not to touch power supply components, pins, leads, or solder connections. Figure 27: Removing an AC Power Supply from an TCX1000-ILA Figure 28: Removing a DC Power Supply from an TCX1000-ILA Place the power supply in the antistatic bag or on the antistatic mat placed on a flat, stable surface.
  • Page 66: Of Electrostatic Discharge Damage" On Page

    Using both hands, place the power supply in the power supply slot on the FRU panel of the TCX1000-ILA and slide it in until it is fully seated and the locking lever slides into place.
  • Page 67: Maintaining The Tcx1000-Ila Fiber-Optic Cables

    NOTE: Each power supply must be connected to a dedicated power source outlet. NOTE: If you have a Juniper Care service contract, register any addition, change, or upgrade of hardware components at https://www.juniper.net/customers/support/tools/updateinstallbase/ . Failure to do so can result in significant delays if you need replacement parts. This note does not apply if you replace existing components with the same type of component.
  • Page 68: Connecting A Fiber-Optic Cable

    Cover the fiber-optic cable connector and the optical connector with the respective rubber safety caps. Connecting a Fiber-Optic Cable Before you connect a fiber-optic cable to an TCX1000-ILA, ensure that you have taken the necessary precautions for safe handling of lasers (see “Laser Safety Warnings for Class 1M Juniper Networks Devices”...
  • Page 69 Chapter 4: Maintaining Components To connect a fiber-optic cable to an optical connector in the TCX1000-ILA (see Figure 31 on page 69): If the fiber-optic cable is covered by a rubber safety cap, remove the cap. Save the cap. Figure 31: Connecting a Fiber-Optic Cable...
  • Page 70: Maintaining Fiber-Optic Cables

    Fiber-optic cables connect to optical transceivers that are installed in Juniper Networks devices. When you unplug a fiber-optic cable from the TCX1000 connector, close the rubber safety caps over the connector and on the end of the cable. Anchor fiber-optic cable to avoid stress on the connectors. When attaching a fiber-optic cable to a connector, be sure to secure the fiber-optic cable so that does not support its own weight as it hangs to the floor.
  • Page 71: Uninstalling An Tcx1000-Ila From A Rack Or Cabinet

    Connecting the TCX1000-ILA to Power on page 50 Uninstalling an TCX1000-ILA from a Rack or Cabinet If you need to remove an TCX1000-ILA to return it or relocate an installed TCX1000-ILA, perform the following procedure. (The remainder of this topic uses rack to mean rack or cabinet.)
  • Page 72 Use a screwdriver to remove the front-mounting screws that attach the chassis mounting brackets to the rack or cabinet. Remove the TCX1000-ILA from the rack. Transport the TCX1000-ILA to your desired new location or pack it to prepare to return (see “Returning a Hardware Component to Juniper Networks, Inc.” on page 75).
  • Page 73: Components

    Returning the TCX1000-ILA Chassis or Components Contacting Customer Support on page 73 Locating the Serial Number on an TCX1000-ILA Chassis or Component on page 74 Returning a Hardware Component to Juniper Networks, Inc. on page 75 Guidelines for Packing Hardware Components for Shipment on page 76...
  • Page 74: Locating The Serial Number On An Tcx1000-Ila Chassis Or Component

    Returning a Hardware Component to Juniper Networks, Inc. on page 75 Locating the Serial Number on an TCX1000-ILA Chassis or Component If you are returning an TCX1000-ILA or an TCX1000-ILA field-replaceable unit (FRU) to Juniper Networks for repair or replacement, you must locate the serial number of the device or FRU.
  • Page 75: Returning A Hardware Component To Juniper Networks, Inc

    Returning a Hardware Component to Juniper Networks, Inc. on page 75 Returning a Hardware Component to Juniper Networks, Inc. In the event of a hardware failure, please contact Juniper Networks, Inc. to obtain a Return Material Authorization (RMA) number. This number is used to track the returned material at the factory and to return repaired or new components to the customer as needed.
  • Page 76: Guidelines For Packing Hardware Components For Shipment

    Do not stack any of the hardware components. Packing an TCX1000-ILA Chassis or Component for Shipping If you are returning an TCX1000-ILA or component to Juniper Networks for repair or replacement, pack the item as described in this topic. Before you pack an TCX1000-ILA or component: Ensure that you have taken the necessary precautions to prevent electrostatic discharge (ESD) damage.
  • Page 77: Packing An Tcx1000-Ila For Shipping

    Remove the TCX1000-ILA from the rack or cabinet. See “Returning the TCX1000-ILA Chassis or Components” on page To return the accessories or FRUs with the TCX1000-ILA, pack them as instructed in “Packing TCX1000-ILA Components for Shipping” on page Place the TCX1000-ILA in an antistatic bag.
  • Page 78: Packing Tcx1000-Ila Components For Shipping

    Close the top of the cardboard shipping box and seal it with packing tape. Write the RMA number on the exterior of the box to ensure proper tracking. See “Returning a Hardware Component to Juniper Networks, Inc.” on page 75 instructions on obtaining an RMA number.
  • Page 79: Troubleshooting

    Troubleshooting the TCX1000-ILA Troubleshooting Resources Overview on page 79 Troubleshooting Resources Overview To troubleshoot a TCX1000-ILA, you use LEDs on the ports, management panel, and components. LEDs—When the TCX1000-ILA detects an alarm condition, it lights the red or yellow alarm LED on the management panel as appropriate. In addition, you can also use component LEDs to troubleshoot the TCX1000-ILA.
  • Page 80 TCX1000 Inline Amplifier Hardware Guide Copyright © 2019, Juniper Networks, Inc.
  • Page 81: Safety And Compliance Information

    Grounded Equipment Warning on page 93 Radiation from Open Port Apertures Warning on page 93 Laser Safety Warnings for Class 1M Juniper Networks Devices on page 94 Maintenance and Operational Safety Guidelines and Warnings on page 96 General Electrical Safety Guidelines and Warnings on page 101...
  • Page 82: General Safety Guidelines And Warnings

    TCX1000 Inline Amplifier Hardware Guide General Safety Guidelines and Warnings The following guidelines help ensure your safety and protect the device from damage. The list of guidelines might not address all potentially hazardous situations in your working environment, so be alert and exercise good judgment at all times.
  • Page 83: Definitions Of Safety Warning Levels

    Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Copyright © 2019, Juniper Networks, Inc.
  • Page 84: Qualified Personnel Warning

    TCX1000 Inline Amplifier Hardware Guide Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt.
  • Page 85: Warning Statement For Norway And Sweden

    In addition, you should establish procedures to protect your equipment in the event of a fire emergency. Juniper Networks products should be installed in an environment suitable for electronic equipment. We recommend that fire suppression equipment be available in the event of a fire in the vicinity of the equipment and that all local fire, safety, and electrical codes and ordinances be observed when you install and operate your equipment.
  • Page 86: Installation Instructions Warning

    To keep warranties effective, do not use a dry chemical fire extinguisher to control a fire at or near a Juniper Networks device. If a dry chemical fire extinguisher is used, the unit is no longer eligible for coverage under a service agreement.
  • Page 87: Chassis And Component Lifting Guidelines

    Attention Cet appareil est à installer dans des zones d'accès réservé. Ces dernières sont des zones auxquelles seul le personnel de service peut accéder en utilisant un outil spécial, un mécanisme de verrouillage et une clé, ou tout Copyright © 2019, Juniper Networks, Inc.
  • Page 88: Ramp Warning

    TCX1000 Inline Amplifier Hardware Guide autre moyen de sécurité. L'accès aux zones de sécurité est sous le contrôle de l'autorité responsable de l'emplacement. Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Ein Bereich mit beschränktem Zutritt ist ein Bereich, zu dem nur Wartungspersonal mit einem Spezialwerkzeugs, Schloß...
  • Page 89: Rack-Mounting And Cabinet-Mounting Warnings

    De onderstaande richtlijnen worden verstrekt om uw veiligheid te verzekeren: De Juniper Networks switch moet in een stellage worden geïnstalleerd die aan een bouwsel is verankerd. Dit toestel dient onderaan in het rek gemonteerd te worden als het toestel het enige in het rek is.
  • Page 90 Les directives ci-dessous sont destinées à assurer la protection du personnel: Le rack sur lequel est monté le Juniper Networks switch doit être fixé à la structure du bâtiment. Si cette unité constitue la seule unité montée en casier, elle doit être placée dans le bas.
  • Page 91 Le seguenti direttive vengono fornite per garantire la sicurezza personale: Il Juniper Networks switch deve essere installato in un telaio, il quale deve essere fissato alla struttura dell'edificio. Questa unità deve venire montata sul fondo del supporto, se si tratta dell'unica unità...
  • Page 92 Para garantizar su seguridad, proceda según las siguientes instrucciones: El Juniper Networks switch debe instalarse en un bastidor fijado a la estructura del edificio. Colocar el equipo en la parte inferior del bastidor, cuando sea la única unidad en el mismo.
  • Page 93: Grounded Equipment Warning

    Varoitus Koska portin aukosta voi emittoitua näkymätöntä säteilyä, kun kuitukaapelia ei ole kytkettynä, vältä säteilylle altistumista äläkä katso avoimiin aukkoihin. Copyright © 2019, Juniper Networks, Inc.
  • Page 94: Laser Safety Warnings For Class 1M Juniper Networks Devices

    öppningar. Laser Safety Warnings for Class 1M Juniper Networks Devices Juniper Networks devices are equipped with laser transmitters, which are considered a Class 1 Laser Product by the U.S. Food and Drug Administration and are evaluated as a Class 1 Laser Product per EN 60825-1 requirements.
  • Page 95: Class 1M Laser Product Warning

    Warnung Class 1 LED-Produktwarnung. Avvertenza Avvertenza prodotto LED di Classe 1. Advarsel LED-produkt i klasse 1. Aviso Produto de classe 1 com LED. ¡Atención! Aviso sobre producto LED de Clase 1. Varning! Lysdiodprodukt av klass 1. Copyright © 2019, Juniper Networks, Inc.
  • Page 96: Laser Beam Warning

    TCX1000 Inline Amplifier Hardware Guide Laser Beam Warning WARNING: Do not stare into the laser beam or view it directly with optical instruments. Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten. Varoitus Älä katso säteeseen äläkä tarkastele sitä suoraan optisen laitteen avulla.
  • Page 97: Battery Handling Warning

    Desechar las baterías gastadas según las instrucciones del fabricante. Varning! Explosionsfara vid felaktigt batteribyte. Ersätt endast batteriet med samma batterityp som rekommenderas av tillverkaren eller motsvarande. Följ tillverkarens anvisningar vid kassering av använda batterier. Copyright © 2019, Juniper Networks, Inc.
  • Page 98: Jewelry Removal Warning

    TCX1000 Inline Amplifier Hardware Guide Jewelry Removal Warning WARNING: Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches. Metal objects heat up when connected to power and ground and can cause serious burns or can be welded to the terminals.
  • Page 99: Lightning Activity Warning

    Varning! Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar. Operating Temperature Warning WARNING: To prevent the device from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature. To Copyright © 2019, Juniper Networks, Inc.
  • Page 100 6 in. (15.2 cm) of clearance around the ventilation openings. Waarschuwing Om te voorkomen dat welke switch van de Juniper Networks router dan ook oververhit raakt, dient u deze niet te bedienen op een plaats waar de maximale aanbevolen omgevingstemperatuur van 40°...
  • Page 101: Product Disposal Warning

    The intrabuilding ports on the device are suitable for connection to intrabuilding or unexposed wiring or cabling only. The addition of primary protectors is not sufficient protection for connecting these interfaces metallically to OSP wiring. Copyright © 2019, Juniper Networks, Inc.
  • Page 102: Action To Take After An Electrical Accident

    TCX1000 Inline Amplifier Hardware Guide CAUTION: Before removing or installing components of a device, connect an electrostatic discharge (ESD) grounding strap to an ESD point and wrap and fasten the other end of the strap around your bare wrist. Failure to use an ESD grounding strap could result in damage to the device.
  • Page 103: Prevention Of Electrostatic Discharge Damage

    103). If you are returning a component, place it in an antistatic bag before packing it. Figure 35: Placing a Component into an Antistatic Bag CAUTION ELECTROSTATIC SENSITIVE DEVICES DO NOT OPEN OR HANDLE EXCEPT AT A STATIC-FREE WORKSTATION Copyright © 2019, Juniper Networks, Inc.
  • Page 104: Ac Power Electrical Safety Guidelines

    TCX1000 Inline Amplifier Hardware Guide CAUTION: ANSI/TIA/EIA-568 cables such as Category 5e and Category 6 can get electrostatically charged. To dissipate this charge, always ground the cables to a suitable and safe earth ground before connecting them to the system.
  • Page 105: Ac Power Disconnection Warning

    TCX1000-ILA DC Power Electrical Safety Guidelines A DC-powered optical TCX1000-ILA is equipped with a DC terminal block that is rated for the power requirements of a maximally configured TCX1000-ILA. To supply sufficient power, terminate the DC input wiring on a facility DC source capable of supplying at least 10 A @ –48 VDC or 5 A @ –60 VDC per input for the DC power supply.
  • Page 106: Dc Power Copper Conductors Warning

    Run two wires from the circuit breaker box to a source of 48 VDC or 60 VDC. A DC-powered TCX1000-ILA is intended only for installation in a restricted-access location. In the United States, a restricted-access area is one in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical Code ANSI/NFPA 70.
  • Page 107 (CC) esté cortada (OFF). Para asegurarse de que toda la alimentación esté cortada (OFF), localizar el interruptor automático en el panel que alimenta al circuito de corriente continua, cambiar el interruptor automático a la posición de Apagado (OFF), Copyright © 2019, Juniper Networks, Inc.
  • Page 108: Dc Power Grounding Requirements And Warning

    TCX1000 Inline Amplifier Hardware Guide y sujetar con cinta la palanca del interruptor automático en posición de Apagado (OFF). Varning! Innan du utför någon av följande procedurer måste du kontrollera att strömförsörjningen till likströmskretsen är bruten. Kontrollera att all strömförsörjning är BRUTEN genom att slå AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast överspänningsskyddets omkopplare...
  • Page 109: Dc Power Wiring Sequence Warning

    –48 V. Al desconectar potencia, la secuencia apropiada del cableado es –48 V a –48 V, +RTN a +RTN, entonces molió para moler. Observe que el alambre de tierra se debe conectar siempre primero y desconectar por último. Copyright © 2019, Juniper Networks, Inc.
  • Page 110: Dc Power Wiring Terminations Warning

    TCX1000 Inline Amplifier Hardware Guide Observe que el alambre de tierra se debe conectar siempre primero y desconectar por último. ¡Atención! Wire a fonte de alimentação de DC Usando os talões apropriados na extremidade da fiação. Ao conectar a potência, a seqüência apropriada da fiação é...
  • Page 111: Multiple Power Supplies Disconnection Warning

    Pour supprimer tout courant électrique de l'unité, tous les cordons d'alimentation doivent être débranchés. Warnung Diese Einheit verfügt über mehr als einen Stromanschluß; um Strom gänzlich von der Einheit fernzuhalten, müssen alle Stromzufuhren abgetrennt sein. Copyright © 2019, Juniper Networks, Inc.
  • Page 112: Tcx1000-Ila Agency Approvals And Compliance Statements

    Compliance Statements for EMC Requirements on page 113 Compliance Statements for Environmental Requirements on page 114 Compliance Statements for NEBS on page 115 TCX1000-ILA Compliance Statements for Acoustic Noise on page 115 TCX1000-ILA Agency Approvals The TCX1000-ILA complies with the following standards: Safety CAN/CSA-C22.2 No.
  • Page 113: Compliance Statements For Emc Requirements

    EN 61000-4-11 Voltage Dips and Short Interruptions EN 61000-3-2 Harmonics ETSI EN-300386-2 Telecommunication Network Equipment. Electromagnetic Compatibility Requirements The TCX1000-ILA is designed to comply with the following standard: NEBS Level 3 GR-63-CORE: Physical Protection GR-1089-CORE: EMC and Electrical Safety for Network Telecommunications...
  • Page 114: Canada

    TCX1000 Inline Amplifier Hardware Guide Canada CAN ICES-3 (A)/NMB-3(A) European Community This is a Class A product. In a domestic environment, this product might cause radio interference in which case the user might be required to take adequate measures. Israel Translation from Hebrew—Warning: This product is Class A.
  • Page 115: Compliance Statements For Nebs

    You must provision a readily accessible device outside of the equipment to disconnect power. The device must also be rated based on local electrical code practice. TCX1000-ILA Compliance Statements for Acoustic Noise Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 70dB(A) oder weniger gemäss EN ISO 7779 Translation: The emitted sound pressure is below 70dB(A) per EN ISO 7779.