4.Troubleshooting

Following are a few common problems that may occur during
operation and some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of the power and the main fuse.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX cables to see if linked
correctly.
2. If the DMX address is showing but no response to the controller,
check the address settings and DMX polarity.
3. Try another DMX controller.
C. No response to the sound
1. Make sure the unit is not receiving a DMX signal.
2. Check the microphone to see if it is good by tapping it. The
microphone is located on the bottom plate of the unit.

5. Fixture Cleaning

The cleaning of external optical lenses must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in
Null
Blackout when Gobo changes
Null
Reset All
Null
Sound Active
0~100%
which the fixture operates: damp, smoky or particularly dirty surrounding
can cause a greater accumulation of dirt on the unit's optics.
Clean with a soft cloth using normal glass cleaning fluid or mild soapy
water.
Ÿ Always dry the parts carefully.
Ÿ
Clean the external optics at least every 20 days.