(2) Power Control Configuration submenu
From the Server menu, move the cursor to Power Control Configuration and then press the <Enter> key to
show its submenus.
For details about the options, see the table below.
AC-LINK
Power ON Delay Time Mode
Delay Time
Standby Power Save
Cold Redundant Mode
Option
Parameter
Stay Off
[Last State]
Power On
[Manually Setting]
Random
[45]-600
[Disabled]
Enabled
[Disabled]
Enabled
Express5800/R120e-1M, R120e-2M Maintenance Guide
Descriptions
Specify AC link feature. Specify how the DC power
state should be when the AC power is supplied again
after loss of power. (See the table below)
Select a method to specify the delay time before
powering on DC power. Available options are:
"User-specified value" or "random value".
This option is selectable when Power On or Last
State is specified in AC-LINK.
Specify the delay time within the range between "xx"
and 600 seconds. The minimum configurable time is
displayed when executing Load Setup Defaults.
This menu appears when Manually Setting is
specified for Power ON Delay Time Mode.
Enable or disable the feature that saves the standby
power on standby. If this option is set to Enabled, the
AC-LINK setting is fixed to Power On automatically
and cannot be changed. With AC power off state,
management, monitoring, and power-on of server are
disabled on remote site. Powering on the server is
available only by pressing the POWER switch on the
server.
If AC-LINK setting is changed from the remote site with
this option being set, you need to press the POWER
switch twice to power on the server.
Enable or disable Cold Redundancy feature.
For details, refer to user's guide.
R120e-1M:Chapter 2 (1.19.1 Cold Redundant Feature)
R120e-2M:Chapter 2 (1.27.1 Cold Redundant Feature)
[