Alternate Floor Protection Calculation - Quadra-Fire 41I-ACC-BK Installation Manual

4100i acc wood insert automatic combustion control (acc)
Table of Contents

Advertisement

0" - 1-3/4"
Thermal protection
required (1/2 inch of
R=2.38)
1-3/4" or more, Ember protection
Thermal Protection
Floor height 0" to 1-3/4" (0 to 44mm)
below insert base.
Floor height greater than 1-3/4" (44mm)
below insert base.
January 10, 2020
only
USA &
CANADA
R=2.38
Only ember
protection
required.
7045-910I
C. Alternate Floor Protection Calculation
Material
Thermal Resistance: R value
The R value is a measure of a material's resistance to heat
transfer.
R value is convenient when more than one material is used
since you can add the R values together, whereas you can
not do this for k value.
The HIGHER the R factor means less heat is being
conducted through the non-combustible material to the
combustible material beneath it.
The R value of a material must be equal or larger then the
required R value to be acceptable.
4100 Insert ACC
11