4100 Insert ACC
B. Clearances to Combustibles
32-1/8 in
(816mm)
USA 18-1/8 in (460mm)
CANADA
22-1/8 in (562mm)
NOTE: If trim measurement is over 3/4 in (19mm) in depth
use mantle or side clearance to combustibles.
44-1/8 in
44-1/8 in
1121mm
1121mm
(See next page for thermal protection
In Canada a full length 6 inch (152mm) S635 flue liner required as per ULC S628.
In USA a minimum 5 ft length (1.82m), 6 inch (152mm) diameter flue liner is required as per UL 1482.
WARNING
Fire Risk.
•
Comply with all minimum clearances to
combustibles as specified.
•
Failure to comply may cause house fire.
10
TOP TRIM
22-5/8 in
(575mm)
HEARTH
EXTENSION
12in max
12in max
MANTEL
USA 23-1/8 in (587mm)
USA 23-1/8 in (587mm)
CANADA 25-1/8 in (638mm)
CANADA 25-1/8 in (638mm)
HEARTH EXTENSION
requirements)
United States and Canada (UL and ULC)
42-1/8 in
(1070mm)
Minimum Opening
Dimensions
A
Height
Front Width (Steel
Surround)
B
Front Width (Cast Trim
Steel Surround)
C
Back Width
Depth (Steel Surround)
D
Depth (Cast Trim Steel
Surround)
NOTE: Minimum opening dimensions include a 1/4" (6mm)
clearance around unit.
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having
jurisdiction
7045-910I
A
D
C
B
Inches
21-3/4
30-1/4
30-1/4
24-1/4
16-1/2
16-1/2
January 10, 2020
Millimeters
552
768
768
616
419
419