G500 Dishwashers
Technical Information
6.1.1.2
Checking Additional Functions
To check which additional functions are operative, press one of the eight
switches from "Universal 65° plus" to "Gentle 45°" to display the additional
functions listed in Section 6.1.1.3.
A two-digit figure will appear in the display. The first digit indicates the
identification number of the additional function (refer to Table 6-1) and the
second digit shows whether the standard function has been altered or not
(0 = standard factory setting, 1 = Optional setting).
Figure 6-2: Digital Display
111