10-3. Indoor Unit
10-3-1. Installation place
• A place which provides the spaces around the indoor
unit as shown in the diagram
• A place where there are no obstacles near the air inlet
and outlet
• A place which allows easy installation of the piping to
the outdoor unit
• A place which allows the front panel to be opened
• The indoor unit shall be installed at least 2.5 m height.
Also, it must avoided to put anything on the top of the
indoor unit.
CAUTION
• Direct sunlight to the indoor unit's wireless
receiver should be avoided.
• The microprocessor in the indoor unit should not
be too close to RF noise sources.
(For details, see the owner's manual.)
<Remote control>
• A place where there are no obstacles such as a
curtain that may block the signal from the indoor
unit.
• Do not install the remote control in a place exposed
to direct sunlight or close to a heating source, such
as a stove.
• Keep the remote control at least 1 m apart from the
nearest TV set or stereo equipment. (This is
necessary to prevent image disturbances or noise
interference.)
• The location of the remote control should be
determined as shown below.
(Side view)
Remote
Reception
control
range
Fig. 10-3-1
(Top view)
Indoor unit
Remote
control
10-3-2. Cutting a hole and mounting installation
<Cutting a hole>
When installing the refrigerant pipes from the rear.
To the center of the pipe hole
1. After determining the pipe hole position on the
mounting plate (A), drill the pipe hole (∅ 65 mm) at
a slight downward slant to the outdoor side.
NOTE
• When drilling a wall that contains a metal lath, wire
lath or metal plate, be sure to use a pipe hole brim
ring sold separately.
<Mounting the installation plate>
Indoor unit outline
300
200
55
Pipe hole
Drain hose position
<Space allows under the indoor unit>
• Space allows for moving range of the air inlet grille
and horizontal louver in operation above curtain
rails, window cornice or other objects.
Air inlet grille
Distance between
bottom of indoor unit
to maximum horizontal
louver opening
- 60 -
Pipe hole
120 mm
Fig. 10-3-2
Recommended mounting screw positions
Hook
55
Hook
Hook
Thread
Weight
Drain hose position
Fig. 10-3-3
460
130
Horizontal louver
Fig. 10-3-4
Ø65 mm
350
200
Pipe hole
(Unit : mm)
Curtain rails,
window cornice
or other objects