Symptom: Heat Pump Failure; Symptom: The System Is Making Gurgling Noises After Commissioning - Daikin EHVX-E6V User Reference Manual

Table of Contents

Advertisement

7
|
Troubleshooting

7.5 Symptom: Heat pump failure

7.6 Symptom: The system is making gurgling noises after commissioning

User reference guide
54
When the heat pump fails to operate, the backup heater and/or booster heater
can serve as an emergency heater. It then takes over the heat load either
automatically or by manual interaction.
When Emergency is set to Automatic and a heat pump failure occurs:
-
For EHVH/X: The backup heater automatically takes over the domestic hot
water production and space heating.
-
For EHBH/X: The backup heater automatically takes over the heat load, and the
booster heater in the optional tank takes over the domestic hot water
production.
When Emergency is set to Manual and a heat pump failure occurs, the
domestic hot water heating and space heating stops.
To manually recover it via the user interface, go to the Malfunctioning main
menu screen and confirm whether the backup heater and/or booster heater can
take over the heat load or not.
Alternatively, when Emergency is set to:
-
auto SH reduced/DHW on, space heating is reduced but domestic hot
water is still available.
-
auto SH reduced/DHW off, space heating is reduced and domestic hot
water is NOT available.
-
auto
SH
normal/DHW
domestic hot water is NOT available.
Similarly as in Manual mode, the unit can take the full load with the backup
heater and/or booster heater if the user activates this via the Malfunctioning
main menu screen.
When the heat pump fails,
Possible cause
Heat pump is damaged.
INFORMATION
When the backup heater or booster heater takes over the heat load, electricity
consumption will be considerably higher.
Possible cause
There is air in the system.
Various malfunctions.
(a)
We recommend to purge air with the air purge function of the unit (to be performed by
the installer). If you purge air from the heat emitters or collectors, mind the following:
off, space heating operates as normally but
or
will appear on the user interface.
See
"7.1 To display the help text in case
of a
malfunction" [
Purge air from the system.
Check if
home screen of the user interface. See
"7.1 To display the help text in case of a
malfunction" [
information about the malfunction.
EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V+6V+9W
Corrective action
4
 52].
Corrective action
(a)
or
is displayed on the
4
 52] for more
Daikin Altherma 3 R F+W
4P629087-1 – 2020.08