5.1 View the IP and MAC Addresses

When the power supply is operating with the LAN enabled, the IP and MAC addresses may be
viewed on the front panel by following these steps:
To view the IP address:
1. Press the Remote switch. Move the Voltage Encoder until "IP" is seen on the Voltage Display.
2. Press the Voltage encoder and move the encoder to view the IP address. The voltage display
will show IP1-IP4 as you move the encoder. The current display will show the required IP.
To view the MAC address:
1. Press the Remote switch. Move the Voltage Encoder until "mAC" is seen on the Voltage Display.
2. Press the Voltage encoder and move the encoder to view the MAC address. The voltage display
will show mAC1- mAC6 as you move the encoder. The current display will show the required MAC.

5.2 Change the IP Address

The LAN allows you change all four numbers (octets) of the IP address from the front panel.
The IP address has four numbers (ex: "10.97.4.4"). Each number may be set to any value from 1-254.
To change the IP address:
1. Press the remote button. Move the Voltage Encoder until IP is seen on the Voltage Display
2. Press the Voltage encoder and then move the encoder to view the IP address. The voltage
display will show IP1-IP4 as you move the encoder. The Current display shows the required IP
address. Move the Current encoder to change the IP address and then press the encoder.
3. 'LAn' will be shown on Voltage Display and 'HOLd' will be shown on Current Display for about
1 sec.
4. If another device is using the same address you want to set, the front panel LED will blink,
and the address will revert to it's previous status. Press any button to stop the blinking.
When you change the IP address from the front panel or ( LAN>Cofigure>Modify Page), the RMX-
410x LAN will switch to STATIC addressing. ( DHCP and Auto-IP addressing will be disabled)

5.3 LAN Reset

To reset the power supply to the factory default LAN settings:
1. Press the remote button. Move the Voltage Encoder until "rST" is seen on the Voltage Display.
2. Press the Voltage encoder. rST will be seen on the current display.
3. Press the Current encoder to reset the system.
4. 'LAn' will be shown on Voltage Display and 'HOLd' will be shown on Current Display for about 1 sec.
5. It may be required to toggle the AC ON/OFF switch.