Power Supply Unit Selection
Hybrid IP-PBX needs an optional power supply unit (PSU) suitable for its configuration. Calculate the amount of "load figures"
from the type and number of equipment to be connected, and determine the type of PSU that will be required.
Load Figure Calculation
PT
Extension Card *1
*1 Only the extension cards that can support SLTs count for the load figures.
PSU Capability
Each PSU supports a different amount of load figures.
PSU Type
PSU-S (KX-TDA0108XJ/X)
PSU-M (KX-TDA0104XJ/X)
PSU-L (KX-TDA0103XJ/X)
Equipment Type
DPT (T76xx series and T7560, T7565)
Other DPT/APT/DSS Console
DHLC8
SLC8
SLC16
MSLC16
CS
ISDN Extension
Voice Mail
Maximum Load Figures
64
128
512
10
Load Figure
1
4
8
8
16
16
4
2
1
Available
Available for the KX-TDA100
Available for the KX-TDA100 and KX-TDA200
Available for the KX-TDA200