Timer Programming; Anti-Freeze Mode - Sapho KTX-C User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 48

Timer programming

Turn on the device by pressing .
Press and hold
→ button ON or OF will
start flashing
Activate (On) or deactivate (Of) the mode
with the use of
and
. Confirm by
pressing .
Clock field is flashing on the display pan-
el and T1 is on
Set the START of the first time zone with
the use of
and
. Confirm by press-
ing .
Set the START of subsequent time
zones T2 – T4 with the use of
Confirm by pressing .
Temperature field is flashing on the display
panel and T1 is on.
Set the required TEMPERATURE for T1
zone using
and
. Confirm by press-
ing .
Set the required TEMPERATURES for the
time zones T2 – T4.
Confirm by pressing .
68
User Manual — Electric Heating Element
and
.
Display panel is no longer flashing, TIMER
icon and a relevant time zone code T(1-4)
depending on current time are on
TIMER programming is finished.
Attention: When the 24 hour TIMER is on, the user can temporari-
ly change the set temperature. When the TIMER starts its next pre-
set program, all the manually changed settings will be cancelled.
While the 24 hour TIMER is on, it is possible to use the DRYER
MODE — regardless of the current device status and the set pro-
gram, the device will start operating at the DRYER MODE settings.
When the DRYER MODE ends, the device returns to the 24 hour
TIMER mode. (refer to DRYER MODE section).

Anti-freeze mode

When the device is switched off with
TIMER mode) and remains connected to the mains, it will switch
itself back on automatically when the ambient temperature falls
below 6°C, to prevent the heating agent from freezing. The dis-
play unit will show letters 'AF', until the anti-freeze mode finishes,
which is when the temperature rises above 6°C.
button (or when in 24 hour