Panasonic GA-MLi8TPoE+ Installation Manual page 13

Hide thumbs Also See for GA-MLi8TPoE+:
Table of Contents

Advertisement

Power LED
PoE LIM. LED
Temperature sensor LED
Fan sensor LED
LED Display change
button
 POWER LED (Power)
Green Light
Off
 PoE LIM. LED (PoE limit)
For silent fan control high-speed (High)* For factory default
Off
Green Light
Orange Blink
For silent fan control low-speed (Low)
Off
Green Light
Orange Blink
 TEMP LED (Temperature sensor)
Green Light
Orange Blink
 FAN (Fan sensor) LED
Green Light
Orange Blink
 STATUS/ECO LED (Status/ECO mode)
Green Light
Green Blink
Orange Light
Orange Blink
 GIGA (GIGA mode) LED
Green Light
 FULL (DUPLEX mode) LED
Green Light
 LOOP HISTORY LED (Loop History mode)
Green Light
Green Blink
Off
: Power is ON.
: Power is OFF.
: Supplying power in the range from 0 to 109 W.
: Supplying power in the range from 109 to 124 W.
: A single port's power supply is exceeding the upper limit, or
the total power supply of the Ethernet Switch is exceeding 124 W.
: Supplying power in the range from 0 to 47 W.
: Supplying power in the range from 47 to 62 W.
: A single port's power supply is exceeding the upper limit, or
the total power supply of the Ethernet Switch is exceeding 62 W.
: The system is normally operating.
: The temperature exceeded the set threshold of the internal
temperature sensor.
Set threshold of the internal temperature sensor: 74°C
(factory default)
: The system is normally operating.
: Fan failure
: Operating in status mode.
: Operating in ECO mode.
All Port LEDs (left) are turned off.
: Starting
: Malfunction (Contact the seller.)
: Operating in GIGA mode.
: Operating in DUPLEX mode.
: Operating in Loop History mode.
: Loop is occurring, or occurred within
the last 3 days.
: No loop detection.
Status/ECO mode LED
GIGA mode LED
DUPLEX mode LED
Loop History mode LED
13