AUXILIARY POWER OPERATION:

Start the engine and set the IDLER control switch to
the desired operating mode. Full power is available
regardless of the welding control settings, if no weld-
ing current is being drawn.
The auxiliary power of the Ranger® 305D (AU) con-
sists of two 15Amp 240VAC single phase receptacles.
The auxiliary power receptacles should only be used
with three wire grounded type plugs or approved dou-
ble insulated tools with two wire plugs.
The current rating of any plug used with the system
must be at least equal to the current capacity of the
associated receptacle.
NOTE: The 240 V receptacle has two circuits, each of
which measure 120 V to neutral but are of opposite
polarities and cannot be paralleled.

Simultaneous Welding and Auxiliary Power Loads

The above auxiliary power ratings are with no welding
load. Simultaneous welding and power loads are
specified in the following table:
Ranger® 305D (AU) Simultaneous Welding and Power Loads
Ranger® 305D (AU) Extension Cord Length Recommendations
(Use the shortest length extension cord possible sized per the following table.)
Current
Voltage
Load
(Amps)
Volts
(Watts)
15
240
3600
OPERATION
Welding
Output-Amps
0
100
150
200
250
300
* Each receptacle is limited to 15 amps.
Maximum Allowable Cord Length in ft. (m) for Conductor Size
14 AWG
12 AWG
60
(18)
75
(23)
Conductor size is based on maximum 2.0% voltage drop.
RANGER® 305D (AU)
Permissible Power-Watts
(Unity Power Factor)
7200
7200
5600
4200
2300
0
10 AWG
8 AWG
150
(46)
225
(69)
B-8
6 AWG
4 AWG
350
(107)
600
(183)