C3.

CHECK MICROWAVE ASSEMBLY

Exhaust Adaptor (absent
on models shipped for
recirculation exhaust)
Place the microwave in its upright position, with the
top of the unit facing up.
The microwave oven may be shipped assembled for
top exhaust (adaptor installed) or for recirculation
exhaust (adaptor absent).
If the microwave was shipped for recirculation
exhaust, skip to C5. If shipped for top exhaust,
proceed with C4.
C4.
ADAPTING MICROWAVE
BLOWER FOR RECIRCULATION
1
Remove
and save
screw that
holds
blower
plate to
microwave.
3
Slide exhaust adaptor to one side and remove it.
NOTE: The exhaust adaptor with damper is not
needed for recirculating models. You may want to
save them for possible future use.
4
Remove and save the screw that holds the blower
motor to the microwave.
Installation Instructions
Back of
Microwave
Lift off the
2
Damper
blower
plate and
attached
adaptor
from the
microwave.
Back of
Microwave
Blower Plate
Back of
Microwave
Blower Motor
Screw
5
Carefully pull out the blower unit. The wires will
extend far enough to allow you to adjust the
blower unit.
6
Roll the blower unit 90° so that fan blade openings
are facing toward the front of the microwave.
BEFORE: Fan Blade
Openings Facing Up
AFTER: Fan Blade
Openings Facing
Forward
7 Place the blower unit back into the opening.
CAUTION: Do not pull or stretch the blower unit
wiring. Make sure the wires are not pinched.