Standard
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-2-30
Mechanical Environmental Conditions
IEC 60068-2-27
IEC 60068-2-6
EMC
IEC 61000-4-6
IEC 61000-4-5
IEC 61000-4-12
IEC 61000-4-4
IEC 61000-4-3
IEC 61000-4-16
IEC 61000-4-8
CISPR 22
EN 55022
EMC Immunity Type Tests for IEEE 1613
Standard
Climatic Environmental Conditions
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
Mechanical Environmental Conditions
IEC 60068-2-6
Power Input
IEC 61000-4-11
EMC and Environmental Type Tests
Method
IEC 61850-3 (5.2)
IEC 61850-3 (5.2)
IEEE 61850-3 (5.2)
IEEE 61850-3 (5.2)
IEC 61850-3 (5.5)
IEC 61850-3 (5.5)
IEC 61850-3
(5.7.1.1)
IEC 61850-3
(5.7.1.2)
IEC 61850-3
(5.7.1.3)
IEC 61850-3
Electrical Fast Transients Immunity
(5.7.1.4)
IEC 61850-3 (5.7.2)
Radiated Susceptibility Immunity
IEC 61850-3 (5.7.3)
Low Frequency Conducted Susceptibility
IEC 61850-3 (5.7.3)
IEC 61850-3 (5.8)
IEC 61850-3 (5.8)
Method
IEEE 1613 (4.1.1)
IEEE 1613 (4.1.1)
High Temperature (Operational)
IEEE 1613 (4.1.2)
IEEE 1613 (4.1.2)
IEEE 1613 (4.1.3)
IEEE 1613 (10)
IEEE 1613 (10)
IEEE 1613 (5.1)
Description
Low Temperature (Storage)
High Temperature (Storage)
Humidity (Operational)
Humidity (Storage)
Shock
Vibration
Conducted Immunity
Surges Immunity
Oscillatory Surge
Magnetic Immunity
Radiated Emission
Conducted Emission
Description
Low Temperature (Operational)
Low Temperature (Storage)
Low Temperature (Storage)
Humidity (Storage)
Shock (Drop)
Vibration
Voltage Variations
Certification
Test Levels
-40 °C (-40 °F), 16 Hour Dwell
-65 °C (-149 °F), 16 Hour Dwell
95% at 55 °C (131 °F) for 96 Hours
95% at 55 °C (131 °F) for 96 Hours
2
30 g (965 ft/s
)
2
2 g (32 ft/s
), 10-150 Hz per Axis
10 Vrms
4 kV L-G
2.5 kV
4 kV
20 V/m
30 V, 300 V Continues 3
V, 30 V 15 Hz to 150 kHz
100 A/m, 1000 A/m (1 sec)
30 MHz to 8 GHz
150 kHz to 30 MHz
Test Levels
-40 °C (-40 °F), 16 Hour Dwell
-65 °C (-149 °F), 16 Hour Dwell
-40 °C (-40 °F), 16 Hour Dwell
85 °C (185 °F), 16 Hour Dwell
95% at 55 °C (131 °F) for 96 Hours
1 m (3.3 ft), 1 Fall per Axis
2
2 g (32 ft/s
), 10-150 Hz per Axis
38.4 to 56 V