Summary of Contents for Endress+Hauser Flowmeter Proline 300
Page 1
Products Solutions Services KA01385D/06/EN/02.19 71424725 2019-02-01 Brief Operating Instructions Flowmeter Proline 300 PROFIBUS DP transmitter with electromagnetic sensor These instructions are Brief Operating Instructions; they are not a substitute for the Operating Instructions pertaining to the device. Brief Operating Instructions part 2 of 2: Transmitter Contain information about the transmitter.
Page 2
Flowmeter Proline 300 Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
Page 3
These Brief Operating Instructions are the Brief Operating Instructions part 2: Transmitter. The "Brief Operating Instructions part 1: Sensor" are available via: • Internet: www.endress.com/deviceviewer • Smart phone/tablet: Endress+Hauser Operations App Detailed information about the device can be found in the Operating Instructions and the other documentation: • Internet: www.endress.com/deviceviewer •...
Flowmeter Proline 300 About this document About this document Symbols used 1.1.1 Safety symbols Symbol Meaning DANGER! DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in WARNING serious or fatal injury.
Page 6
About this document Flowmeter Proline 300 Symbol Meaning Protective Earth (PE) A terminal which must be connected to ground prior to establishing any other connections. The ground terminals are situated inside and outside the device: • Inner ground terminal: Connects the protectiv earth to the mains supply.
Flowmeter Proline 300 Basic safety instructions Basic safety instructions Requirements for the personnel The personnel must fulfill the following requirements for its tasks: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task. ‣ Are authorized by the plant owner/operator.
Verification for borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.
Flowmeter Proline 300 Basic safety instructions Device-specific IT security The device offers a range of specific functions to support protective measures on the operator' s side. These functions can be configured by the user and guarantee greater in-operation safety if used correctly.
Product description Flowmeter Proline 300 Product description The device consists of a Proline 300 transmitter and an electromagnetic Proline Promag sensor. The device is available as a compact version: The transmitter and sensor form a mechanical unit. N ic te r e r g ö...
Flowmeter Proline 300 Installation Installation For detailed information about mounting the sensor, see the Sensor Brief Operating Instructions → 3 Turning the transmitter housing To provide easier access to the connection compartment or display module, the transmitter housing can be turned.
Installation Flowmeter Proline 300 Turning the display module The display module can be turned to optimize display readability and operability. – – – 3 mm A0030035 Depending on the device version: Loosen the securing clamp of the connection compartment cover.
Flowmeter Proline 300 Electrical connection Electrical connection NOTICE The measuring device does not have an internal circuit breaker. ‣ For this reason, assign the measuring device a switch or power-circuit breaker so that the power supply line can be easily disconnected from the mains.
Page 14
Electrical connection Flowmeter Proline 300 Signal cable PROFIBUS DP The IEC 61158 standard specifies two types of cable (A and B) for the bus line which can be used for every transmission rate. Cable type A is recommended. For detailed information about the specification of the connecting cable, see the Operating Instructions for the device.
Page 15
Flowmeter Proline 300 Electrical connection Available cable length 5 m (15 ft)/10 m (35 ft)/20 m (65 ft)/30 m (100 ft) Operating temperature When mounted in a fixed position: –50 to +105 °C (–58 to +221 °F); when cable can move freely: –25 to +105 °C (–13 to +221 °F)
Electrical connection Flowmeter Proline 300 5.1.3 Terminal assignment Transmitter: supply voltage, input/outputs The terminal assignment of the inputs and outputs depends on the individual order version of the device. The device-specific terminal assignment is documented on an adhesive label in the terminal cover.
Page 17
Flowmeter Proline 300 Electrical connection 5.2.1 Connecting the transmitter A0026781 Terminal connection for supply voltage Terminal connection for signal transmission, input/output Terminal connection for signal transmission, input/output or terminal connection for network connection via service interface (CDI-RJ45); optional: connection for external WLAN antenna or...
Page 18
Electrical connection Flowmeter Proline 300 N ic N ic t e r t e r e r g ö f f e r g ö f f iz e iz e t e n t e n r ir r ir...
Page 19
Flowmeter Proline 300 Electrical connection 22 mm 24 mm – A0029816 10. Connect the cable in accordance with the terminal assignment . Signal cable terminal assignment: The device-specific terminal assignment is documented on an adhesive label in the terminal cover.
Electrical connection Flowmeter Proline 300 5.2.2 Connecting the remote display and operating module DKX001 The remote display and operating module DKX001 is available as an optional extra. • The remote display and operating module DKX001 is only available for the following housing version: order code for "Housing": option A "Aluminum, coated"...
Page 21
• Grounding rings can be ordered separately as an accessory from Endress+Hauser . When ordering make sure that the grounding rings are compatible with the material used for the...
Page 22
Electrical connection Flowmeter Proline 300 Potential equalization via grounding electrodes on process connection A0028972 Hexagonal-headed bolts of process connection Integrated grounding electrodes O-ring seal Sensor 5.3.2 Promag P For devices intended for use in hazardous locations, please observe the guidelines in the Ex documentation (XA).
Page 23
Flowmeter Proline 300 Electrical connection Ground cable Copper wire, at least 6 mm (0.0093 in DN 300 DN 350 ≥ ≤ A0029338 2 Potential equalization via ground terminal and pipe flanges Connect both sensor flanges to the pipe flange via a ground cable and ground them.
Page 24
Electrical connection Flowmeter Proline 300 Pipe with a cathodic protection unit This connection method is only used if the following two conditions are met: • Metal pipe without liner or pipe with electrically conductive liner • Cathodic protection is integrated in the personal protection equipment...
Flowmeter Proline 300 Electrical connection Hardware settings 5.4.1 Setting the device address The address must always be configured for a PROFIBUS DP/PA device. The valid address range is between 1 and 126. In a PROFIBUS DP/PA network, each address can only be assigned once.
Page 26
Electrical connection Flowmeter Proline 300 5.4.2 Enabling the terminating resistor To avoid incorrect communication transmission caused by impedance mismatch, terminate the PROFIBUS DP cable correctly at the start and end of the bus segment. • If the device is operated with a baud rate of 1.5 MBaud and under: For the last transmitter on the bus, terminate by setting DIP switch 3 (bus termination) to •...
Flowmeter Proline 300 Electrical connection Ensuring the degree of protection The measuring device fulfills all the requirements for the IP66/67 degree of protection, Type 4X enclosure. To guarantee IP66/67 degree of protection, Type 4X enclosure, carry out the following steps after the electrical connection: Check that the housing seals are clean and fitted correctly.
Operation options Flowmeter Proline 300 Operation options Overview of operation options A0034513 Local operation via display module Computer with Web browser (e.g. Internet Explorer) or with operating tool (e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM) Field Xpert SFX350 or SFX370...
Flowmeter Proline 300 Operation options Structure and function of the operating menu 6.2.1 Structure of the operating menu Operating menu for operators and maintenances Language Operation task-oriented Setup Diagnostics Operating menu for experts Expert function-oriented A0014058-EN 4 Schematic structure of the operating menu 6.2.2...
Operation options Flowmeter Proline 300 Access to the operating menu via the local display X X X X X X 19.184 mA 12.5 X X X X X X Language 20.50 Ã English Deutsch Español Français Xxxxxxx A B C D E F G H I J K M N O P Q R S T U V W +0.000 Xx...
Page 31
Flowmeter Proline 300 Operation options 6.3.1 Operational display Explanatory symbols for the measured value Status area • Depends on the device version, e.g.: The following symbols appear in the status area of the – : Volume flow operational display at the top right: –...
Page 32
Operation options Flowmeter Proline 300 Numeric editor Confirms selection. Moves the input position one position to the left. Exits the input without applying the changes. Inserts decimal separator at the input position. Inserts minus sign at the input position. Clears all entered characters.
Flowmeter Proline 300 System integration Keys and meaning Minus/Enter key combination (press the keys simultaneously) With an operational display: • If keypad lock is active: Press the key for 3 s: Deactivates the keypad lock. • If keypad lock is not active: Press the key for 3 s: Opens the context menu including the option for activating the keypad lock.
Commissioning Flowmeter Proline 300 Commissioning Function check Before commissioning the measuring device: ‣ Make sure that the post-installation and post-connection checks have been performed. • "Post-installation check" checklist → 12 • "Post-connection check" checklist → 27 Setting the operating language...
Flowmeter Proline 300 Commissioning Configuring the measuring device The Setup menu with its submenus and guided wizards is used for fast commissioning of the device. They contain all the parameters required for configuration, such as for measurement or communication. Depending on the device version, not all submenus and parameters are available in every device.
Diagnostic information Flowmeter Proline 300 Diagnostic information Faults detected by the self-monitoring system of the measuring device are displayed as a diagnostic message in alternation with the operational display. The message about remedial measures can be called up from the diagnostic message, and contains important information on the fault.
Need help?
Do you have a question about the Flowmeter Proline 300 and is the answer not in the manual?
Questions and answers