Exhaust gas entering the living space can cause carbon monoxide poisoning. If exhaust gas should leak into the living space:
Shut down the water heater.
Close the gas valve.
Open windows for ventilation.
Immediately call a qualified service technician to inspect the water heater and exhaust vent pipe. Any damages to the exhaust vent pipe
should be repaired immediately. Failure to do so could result in substantial property damage, severe personal injury, or death.
3.
Burn Warning
Take caution when inspecting the water heater, exhaust vent, and/or water pipes. These components can get extremely hot
during water heater operation.
4.
Combustibles and Flammable Material Warning
Do not store combustibles or flammable materials in the vicinity of this water heater. Do not hang clothes from the exhaust
pipe.
Storing flammable or combustible materials near this water heater could result in a fire or explosion, substantial property damage,
severe personal injury, or death.
5.
Check for Water Leaks
Do not attempt to clean the heating system. Call a qualified service technician for service.
If you notice any leaks, immediately call a qualified service technician. Leaks in water heater or piping must be repaired at
once.
C. TROUBLESHOOTING AND GENERAL CAUTIONARY STATEMENTS
DO NOT use this water heater for any purposes other than those specifically described by Westinghouse (to provide domestic hot
water). Using this water heater for unapproved purposes WILL VOID the warranty, and could result in property damage, serious
personal injury, or death.
DO NOT wipe the water heater or control panel with a wet cloth. Doing so may result in an electric shock, substantial property damage,
premature water heater failure, severe personal injury, or death.
DO NOT shut off the water heater for long periods of time during potentially freezing conditions. This water heater has a freeze
protection function. The ceramic heater installed inside of the heater's heat exchanger is designed to protect the water heater from
freezing.
Ensure the exposed water pipes are thermally insulated to prevent damage due to freezing conditions. If the water heater is not to be
used for an extended period of time during freezing conditions, shut down the system and completely drain the water heater.
If the water pipes should freeze, thaw the pipes with a hair dryer or other electric heating device. If this does not work, call a qualified
service technician.
Failure to provide freeze protection could result in substantial property damage due to burst pipes, personal injury, or death.
If the water heater is not to be used for an extended period of time during freezing conditions, consider shutting down the system and
draining it of water. Shut off the gas and cold water supply valves.
DO NOT attempt to disassemble this water heater. Doing so could result in improper water heater operation or premature water heater
failure, substantial property damage, and/or severe personal injury or death due to electric shock, fire, or explosion. If repairs are
required, contact a qualified service technician.
DO NOT touch the exhaust vent or hot water pipes during water heater operation. Doing so could result in substantial personal injury.