General Check - Hitachi YUTAKI S COMBI Series Installation And Operation Manual

Hide thumbs Also See for YUTAKI S COMBI Series:
Table of Contents

Advertisement

6.1

General check

• Make sure that the following conditions related to power supply installation are satisfied:
✓ The power capacity of the electrical installation is large enough to support the power
demand of the YUTAKI system (outdoor unit + indoor unit + DHW tank (if apply)).
✓ The power supply voltage is within ±10% of the rated voltage.
✓ The impedance of the power supply line is low enough to avoid any voltage drop of more
than 15% of the rated voltage.
• Following the Council Directive 2004/108/EC, relating to electromagnetic compatibility, the
table below indicates the Maximum permitted system impedance Z
the user's supply, in accordance with EN61000‑3‑11.
Model
Power supply
~ 230V 50Hz
3N~ 400V 50Hz
~ 230V 50Hz
3N~ 400V 50Hz
• The status of Harmonics for each model, regarding compliance with IEC 61000‑3‑2 and
IEC 61000‑3‑12, is as follows:
Status regarding compliance with IEC 61000‑3‑2 and IEC 61000‑3‑12
Equipment complying with IEC 61000‑3‑2 (*): Professional use
Equipment complying with IEC 61000‑3‑12
Installation restrictions may be applied by supply authorities in relation to harmonics
PMEN0645 rev.0 - 04/2023
Without electric heaters
With electric heater
With DHW tank heater
With electric and DHW tank heaters
Without electric heaters
With electric heater
With DHW tank heater
With electric and DHW tank heaters
Without electric heaters
With electric heater
With DHW tank heater
With electric and DHW tank heaters
Without electric heaters
With electric heater
With DHW tank heater
With electric and DHW tank heaters
at the interface point of
max
Operation mode
Z
(Ω)
max
0.30
6
0.28
0.20
Models
YUTAKI S Combi
tbc
34

Advertisement

Table of Contents
loading

Table of Contents