Moxa Technologies MGate 5121 Series Quick Installation Manual
Moxa Technologies MGate 5121 Series Quick Installation Manual

Moxa Technologies MGate 5121 Series Quick Installation Manual

Hide thumbs Also See for MGate 5121 Series:

Advertisement

Quick Links

MGate 5121 Series
Quick Installation Guide
Version 1.0, June 2023
Technical Support Contact Information
www.moxa.com/support
 2023 Moxa Inc. All rights reserved.
P/N: 1802051210110
*1802051210110*

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MGate 5121 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Moxa Technologies MGate 5121 Series

  • Page 1 MGate 5121 Series Quick Installation Guide Version 1.0, June 2023 Technical Support Contact Information www.moxa.com/support  2023 Moxa Inc. All rights reserved. P/N: 1802051210110 *1802051210110*...
  • Page 2 Overview The MGate 5121 is an industrial Ethernet gateway for CANopen/J1939 and Modbus TCP network communications. Package Checklist Before installing the MGate 5121, verify that the package contains the following items: • 1 MGate 5121 gateway • Quick installation guide (printed) •...
  • Page 3 Color Description Single flash: An error counter warning level has been reached. Double flash: A heartbeat event has occurred. No J1939 I/O configured Steady: CAN bus (J1939) communication is Green receiving or transmitting data. Steady: A communication error occurred [as J1939] 1.
  • Page 4 Dimensions DIN Rail Side DIN Rail - 4 -...
  • Page 5 Wall Mount Reset Button Restore the MGate to factory default settings by using a pointed object (such as a straightened paper clip) to hold the reset button down until the Ready LED stops blinking (approximately five seconds). Hardware Installation Procedure 1.
  • Page 6 The following figure illustrates the two mounting options: Wall- or Cabinet-mounting We provide two metal plates to mount the unit on a wall or inside a cabinet. Attach the plates to the unit’s rear panel with screws. With the plates attached, use screws to mount the unit on the wall.
  • Page 7 Ethernet Port (RJ45) Signal Power Input and Relay Output Pinouts Power Power N.O. Common N.C. Power Power Input 2 Input 2 Input 1 Input 1 Specifications Power Parameters Power Input 12 to 48 VDC Power Consumption 455 mA max. Relays Contact Current Rating Resistive load: 2 A @ 30 VDC Environmental Limits...
  • Page 8 ATTENTION • This device is an open-type equipment and intended to be installed in a suitable enclosure. • If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. •...

Table of Contents