Domestic Hot Water - Daikin ETSH16P50EF Operation Manual

Hide thumbs Also See for ETSH16P50EF:
Table of Contents

Advertisement

4 Quick guide
2 Adjust the desired leaving water temperature.
a
b
2
35
°C
Main zone
a
b
3
45
°C
Additional zone
a Actual leaving water temperature
b Desired leaving water temperature
To change the weather-dependent curve for the space heating/
cooling zones
1 Go to the applicable zone:
Zone
Main zone – Heating
Main zone – Cooling
Additional zone – Heating
Additional zone – Cooling
2 Change the weather-dependent curve.
There are 2 types of WD curves: slope-offset curve (default),
and 2-points curve. If needed, you can change the type in
[2.E] Main zone > WD curve type. The way to adjust the
curve depends on the type.
Slope-offset curve
Slope. When slope is changed,
the new preferred temperature at
X1 is unequally higher than the
preferred temperature at X2.
a
b
c
d
Y4
Y3
Y2
Y1
X1
X2
X1, X2
Outdoor ambient temperature
Y1~Y4
Desired leaving water temperature
a
WD curve before changes
b
WD curve after changes
c
Slope
d
Offset
Possible actions on this screen
Select slope or offset.
Increase or decrease the slope/offset.
When slope is selected: set slope and go to offset.
When offset is selected: set offset.
Confirm changes and return to the submenu.
Operation manual
6
+
+
Go to ...
[2.5] Main zone > Heating WD
curve
[2.6] Main zone > Cooling WD
curve
[3.5] Additional zone >
Heating WD curve
[3.6] Additional zone >
Cooling WD curve
Offset. When offset is changed,
the new preferred temperature at
X1 is equally higher as the
preferred temperature at X2.
a
b
c
d
Y4
Y3
Y2
Y1
X1
X2
2-points curve
Y2
Y1
X1
X2
X1, X2
Outdoor ambient temperature
Y1, Y2
Desired leaving water temperature
Possible actions on this screen
Go through the temperatures.
Change the temperature.
Go to the next temperature.
Confirm changes and proceed.
More information
For more information, see also:
"5.4 Turning operation ON or
control" [ 4  12]
"5.6 Space heating/cooling
Example" [ 4  14]
"5.8 Schedule screen:
"5.9 Weather-dependent
curve" [ 4  15]
▪ User reference guide
4.3

Domestic hot water

To turn tank heating operation ON or OFF
NOTICE
To ensure safe operation of the system, do NOT turn off
DHW when space heating is required.
NOTICE
Disinfection mode. Even if you turn OFF tank heating
operation ([C.3]: Operation > Tank), disinfection mode will
remain active. However, if you turn it OFF while
disinfection is running, an AH error occurs.
1 Go to [C.3]: Operation > Tank.
C.3
Operation
Space heating/cooling
On
Tank
Off
2 Set operation to On or Off.
To change the tank temperature setpoint
In Reheat only mode, you can use the tank temperature setpoint
screen to read out and adjust the storage tank temperature. The
resulting domestic hot water temperature depends on this setpoint
as well as the actual storage tank temperature.
1 Go to [5]: Tank.
5
Tank
OFF" [ 4  11]
ETSH/X(B)16P30+50EF
Daikin Altherma 3 H HT ECH₂O
4P679469-1 – 2022.02