Mechanical and climatic conditions of use
The device is designed for use in locations protected from the effects of the weather. The
conditions of use meet the requirements for EN/IEC 61131-2.
Testing mechanical ambient conditions
For the device SIMATIC IFP Basic, the type and scope of tests for mechanical ambient
conditions are as follows:
Tested for
Vibrations
Shock
Shock pulses within the specified range can be transferred to the display but do not impact
the functionality of the device.
For the device SIMATIC IFP1200 Basic C, if the device is installed with the method of vesa
mounting, the type and scope of tests for mechanical ambient conditions are as follows:
Tested for Test standard
Vibrations
Shock
For the device SIMATIC IFP1200 Basic C, if the device is installed with mounting clip, the type
and scope of tests for mechanical ambient conditions are as follows:
70
Test standard
Vibration test in accordance
with IEC 60068, part 2-6
(sinusoidal)
Shock test in accordance
with IEC 60068, Part 2-27
Vibration test in accordance
with IEC 60068, part 2-6 (si-
nusoidal)
Shock test in accordance with
IEC 60068, Part 2-27
Comments
Type of vibration:
Frequency cycles at a rate of change of 1 oc-
tave/minute.
5 to 8.4 Hz, constant amplitude 3.5 mm
8.4 to 200 Hz, constant acceleration 1 g
Vibration duration:
10 frequency cycles per axis in each of the three mu-
tually vertical axes
Type of shock: Half-sine
Severity of shock:
Peak value 15 g, duration 11 ms
Direction of shock:
3 shocks in ± direction of axis in each of the three axes
vertical to each other
Comments
Type of vibration:
Frequency cycles at a rate of change of 1 octave/minute.
5 to 8.4 Hz, constant amplitude 3.5 mm
8.4 to 200 Hz, constant acceleration 1 g
Vibration duration:
10 frequency cycles per axis in each of the three mutual-
ly vertical axes
Type of shock: Half-sine
Severity of shock:
Peak value 15 g, duration 11 ms
Direction of shock:
3 shocks in ± direction of axis in each of the three axes
vertical to each other