6. SPECIFICATIONS

6.1 Indoor Alarm Display

Power Supply
Enclosure
LED
Audible alarm
Transceiver
Optional relay
output

6.2 Outdoor Transmitter

Power
Enclosure
Transceiver
Probe

6.3 IC and FCC 15 Approval

Contains Model XBEE-PRO Radio, IC:4214A-XBEEPRO
Contains FCC ID: OUR-XBEEPRO
The enclosed device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (i) this
device may not cause harmful interference and (ii) this device
must accept any interference received, including interference
that may cause undesired operation.
Page 16
120VAC, 60 Hz input, 12VDC 5W output, UL
listed, CSA certified, indoor unit, power con-
sumption typically .05 watts, 0.9 watts maximum
during alarm condition
flame retardant ABS
High level, Low level function selectable
tricolor
solid state transducer, 85db @ 10cm
ISM 2.4GHz, 12 channels available, -40°C to
85°C rated, IC and FCC 15 approved
dry contact, 2A@30VAC or VDC, Normally Open
or Normally Closed selectable
four AA batteries, battery life 3 years under nor-
mal operation
PVC NEMA 6P
High level, Low level function selectable
ISM 2.4GHz, 12 channels available, -40°C to
85°C rated, IC and FCC 15 approved
digital RF proximity, stainless steel, type 304 or
316, 22mm diameter x 100mm long, cable - 2
conductor, 18 Ga, SJOOW jacket, 5m (16 feet)
or 10m (32 feet)