4.3.2
Page 14
•
Disconnect power from the indoor alarm display.
•
Open the back cover of the display and move the
jumpers for the code and the channel. See FIG 1.
Replace the cover.
•
Hold the Audio button down while connecting power.
The LED will turn on bright red indicating that
programming mode is entered. Release the button
and the LED will go out.
•
Within 5 seconds, press the button until the LED
turns on, then release.Repeat this for 1 to 6 times to
select the group.
•
Wait for 5 seconds, and the LED will flash back the
same number of times to confirm the group. After
another 5 second delay it will flash once or twice
confirming the channel setting. The display will then
go into normal operation.
Program the outdoor transmitter
•
Disconnect the power from the outdoor transmitter
by removing a battery. Discharge the capacitance by
using a short length of wire to short out the red and
black wires of the battery holder.
•
Move the installer code and channel jumpers to your
selected position. See FIG 3.
•
Hold down the push-button switch while installing
the battery. The LED will turn on bright red indicating
that programming mode is entered. Release the
push-button and the LED will go out.
•
Within 5 seconds, press the button until the LED
turns on, then release. Repeat this 1 to 6 times to
select the group.
•
Wait for 5 seconds and the LED will flash back the
same number of times to confirm the group. After
another 5 second delay it will flash once or twice
confirming the channel setting. The transmitter will
then go into normal operation.