Program The Outdoor Transmitter - Sentry 110 Operating Manual

Liquid level alarm
Hide thumbs Also See for 110:
Table of Contents

Advertisement

Sentry
Liquid Level Alarm
4.3.2
Page 14
Disconnect power from the indoor alarm display.
Open the back cover of the display and move the
jumpers for the code and the channel. See FIG 1.
Replace the cover.
Hold the Audio button down while connecting power.
The LED will turn on bright red indicating that
programming mode is entered. Release the button
and the LED will go out.
Within 5 seconds, press the button until the LED
turns on, then release.Repeat this for 1 to 6 times to
select the group.
Wait for 5 seconds, and the LED will flash back the
same number of times to confirm the group. After
another 5 second delay it will flash once or twice
confirming the channel setting. The display will then
go into normal operation.

Program the outdoor transmitter

Disconnect the power from the outdoor transmitter
by removing a battery. Discharge the capacitance by
using a short length of wire to short out the red and
black wires of the battery holder.
Move the installer code and channel jumpers to your
selected position. See FIG 3.
Hold down the push-button switch while installing
the battery. The LED will turn on bright red indicating
that programming mode is entered. Release the
push-button and the LED will go out.
Within 5 seconds, press the button until the LED
turns on, then release. Repeat this 1 to 6 times to
select the group.
Wait for 5 seconds and the LED will flash back the
same number of times to confirm the group. After
another 5 second delay it will flash once or twice
confirming the channel setting. The transmitter will
then go into normal operation.