Changing Installer Code Indoor Radio Frequency - Sentry 110 Operating Manual

Liquid level alarm
Hide thumbs Also See for 110:
Table of Contents

Advertisement

4.2 Probe Assembly
To access the probe wire terminal block, tilt and lift out the
elctronic board. See FIG 4. Tilt the boars by pressing down on
the lower right corner, at the serial number.
4.3 Changing Installer Code or Radio Frequency
If an installation requires multiple alarms change the programmed
installer code of both the indoor display and the outdoor
transmitter. If there is interference with the wireless signal
change the frequency. There are 16 installer code combinations
and 12 frequencies for a total of 192 combinations.
The installer code factory preset is all jumpers installed not
shorting the two pins. If required, set an installer code unique to
your installation by installing one or more jumpers shorting in the
display and transmitter and then reprogram both.
The frequency factory preset is frequency 3.
Select channel 1 or 2 by installing the jumper off one pin for
Channel #
Group
Frequency
channel 1 or shorting the pins for channel 2. Select a group by
contacting the push-button 1 to 6 times while in programming
mode.
4.3.1
Model 110 Operating Manual
Factory
preset
1
2
1
1
1
2
3
Program the Indoor Display
Sentry
2
1
2
1
3
2
4
5
6
7
Liquid Level Alarm
2
1
2
1
4
5
8
9
10
11
2
6
12
Page 13