Chengdu Ebyte Electronic Technology Co.,Ltd
6.3 Command list
6.3.1Test Command
Note: Used to test whether the serial port communication is normal.
6.3.2 Broadcast name
Inquire
Setting
Parameters
Effective immediately, power off save;
The length of the broadcast name is not more than 16 bytes;
Description
The factory default broadcast name is CDEBYTE_XXXX, which is the last two bytes of the MAC
address.
Query the broadcast name (MAC: 2C:11:65:22:B1:1B)
Instruction: AT+NAME?
Return: +NAME=CDEBYTE_B11B
Example
Set the broadcast name to MY_TEST
Instruction: AT+NAME=MY_TEST
Return: +OK
6.3.3 MAC Address
Inquire
Parameters
Descriptionn
Assume that the local MAC address is 2C:11:65:22:B1:1B
Example
Instruction: AT+MAC?
Return: +MAC=2C:11:65:22:B1:1B
6.3.4 Module characters
Inquire
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd
Command
AT
Command
AT+NAME?
AT+NAME=[para]
Commmand
AT+MAC?
The returned MAC address is a hexadecimal character.
Command
AT+ROLE?
+ NAME =[para]
+OK:success
+ERR=[NUM]:Error
Broadcast name
+ MAC =[para]
MAC Address
+ROLE=[para]
E104-BT53C3 Manual User
Reply
+OK
Reply
Reply
Reply
14