Job Link® System Manometer Probe
2 x AAA Batteries
Tubing with brass fitting
Bulk tubing
Gas adapter
Static pressure tip
Operator's manual
1 Year limited warranty
The JL3MN Job Link® System Manometer Probe sends static pressure or gas pressure measurements directly to the Fieldpiece Job Link app up to 1000 feet (305 meters) away.
Use two JL3MN probes to do even more. Because they are untethered, you don't need long hoses to measure differential pressures. Measure and view real-time return static, supply static, and total external static pressure all at once. Use your static pressure tip with short tubing for accurate static pressure measurements. Measure real-time inlet and manifold pressures simultaneously with 2 Job Link manometers.
Mount your manometer to equipment for hands free use in tight spaces. The powerful rotating magnet holds tight even when the hose is tugged or the equipment shakes. Slide the switch and the app immediately knows which side of the system you're going to place your manometer probe.
CLEANING: Clean the exterior with a damp cloth. Do not use detergents or solvents. Do not apply pressurized air into the connection port.
BATTERIES: When the LED slow-blinks Red, the batteries must be replaced. Ensure the power is OFF. Remove the single screw from the yellow battery cover. Install 2 x AAA batteries. You can also monitor battery life in the Job Link app tool manager.
SENSOR CARE: Store JL3MN in a protective cover when not in use to prevent debris or foreign contaminants from entering the barb tip. Do not pressurize the probe above its max specification.
Prevent damage, do not drill holes blindly into a plenum that houses the evaporator or heat exchanger.
Do not place any part of the manometer on hot surfaces such as exhaust fumes. Doing so can cause personal injury, damage equipment, and void warranty.
Do no apply more than 11.6 psi.
Minimum Device Requirement:
BLE 4.0 devices running iOS® 7.0 or Android™ 5.0
(Latest compatibility at www.fieldpiece.com)
Compatible Media: Dry, non-corrosive gas
Pressure Port: Tube connector for flexible tubing (4.5 to 8mm ID)
Units of Measure: inWC, mmWC, mbar, psi, Pa
Accuracy and Ranges:
inWC: ±(1.5% + 0.02) 0.00 to ± 60.00;
mmWC: ±(1.5% + 0.5) 0.0 to ± 1500.0;
mbar: ±(1.5% + 0.05) 0.00 to ± 150.00;
psi: ±(1.5% + 0.001) 0.000 to ± 2.165;
Pa: ±(1.5% + 5) 0 to ± 14930
Maximum Overload Pressure: 321.08 inWC (11.6 psi; 80.0 kPa)
Battery Type: 2 x AAA, NEDA 24A, IEC LR03
Battery Life: 150 hours typical alkaline. LED slow-blinks red when battery replacement is needed.
Auto Power Off: 2 hours (APO can be disabled)
Wireless Range: 1000 feet (305 meters) line of sight. Obstructions affect distance.
Radio Frequency: 2.4 GHz
Operating Environment: -10°F to 122°F (-23°C to 50°C) at <75% RH
Storage Temperature: -10°F to 140°F (-23°C to 60°C) at <80% RH (with batteries removed)
Temperature Coefficient: 0.1 x (specified accuracy) per 1.8°F (-10°F to 64°F, 82°F to 122°F), per 1°C (-23°C to 18°C, 28°C to 50°C)
Weight: 0.30 lbs (137 g)
US Patent: www.fieldpiece.com/patents
Press for 1 second to power ON/OFF. Tap to zero measurements.
Green slow blink: normal operation
Red slow blink: batteries need to be replaced
The Job Link® System app knows which side you have selected for each probe. Select P1 or P2 and place it on the system appropriately.
Static pressure testing ensures if the equipment is operating within factory specifications.
Prevent symptoms like rough starts or overheating your heat exchanger by checking your gas pressure.
NOTE:
Some pressure taps have a 5/16'' boss instead of an insert screw. In this case, use the included 5/16'' adapter tube. Loosen the tap screw about 1 revolution and slide the tube over the boss.
The probe will automatically power off after 2 hours. To disable APO until powered off, while power is on tap twice. The LED will briefly blink red. To enable APO, while power is on tap
twice. The LED will briefly shine red.