9. MAINTENANCE

High voltage risk. During maintenance or repairs, always stop the unit then unplug it to prevent any risk of
electric shock. The wearing of safety glasses and gloves is recommended when handling unit components to
prevent any risk of injury that could be caused by the presence of thin metal.
9.1 Q
UARTERLY
1. Disconnect power cord.
2. The door of this unit is hinged and maintained closed by 2 latches. Open them and set aside.
3. Clean the inside of the door with a damp cloth.
4. Clean fi lters:
• Remove fi lters.
• Vacuum to remove most of the dust.
• Wash with a mixture of warm water and mild soap. You may add bleach if you wish to
disinfect (one tablespoon per gallon). Rinse thoroughly. Shake fi lters to remove excess water
and let dry.
Note: The optional MERV13 fi lter is a disposable fi lter. It should be replaced when it is too dirty.
Vacuum the MERV13 membrane fi lter quarterly using the dusting brush attachment to extend
its service life.
5. Remove the core.
6. Clean the condensing tray with a damp cloth.
7. Check the exterior air intake hood:
A blocked air vent or fi lter, even partially, could cause the unit to malfunction. The comfort provided by the
unit could be reduced and the risk of unit frost could increase. This could cause unit breakdown and/or damage
to property.
• Make sure there are no leaves, twigs, ice or snow that could be drawn into the vent.
• Clean if necessary.
8. Rotate the blower wheels by hand. If one of the wheels does not rotate easily, contact your installer.
9. Reassemble the components. Pay special attention to the fi lters by making sure that they are engaged in their slots.
10. Close the unit door and reconnect power supply.
11. Reset fi lters, if required. If using an optional main wall control (D
5 seconds to reset the fi lters. If using the A
MERV8
FILTER INCLUDED
E
XHAUST FILTER INCLUDED
Pull the core 3" to 4" out.
Bend the two MERV13 fl aps to form a
45-degree angle, as illustrated below.
45˚
45˚
Install the MERV13 fi lter over the core
as illustrated hereafter.
Push the core and the MERV13 fi lter to
the bottom of the unit.
!
WARNING
CAUTION
optional main wall control, follow the instructions on the touch screen.
DVANCED
VD0494
O
MERV13
PTIONAL
(
EXHAUST FILTER NOT INCLUDED
NOTES: 1. The optional MERV13 fi lter replaces the MERV8 fi lter.
2. MERV13 fi lter and HEPA membrane fi lter have the same installation instructions.
23
A
), press on the INT/AUTO button for
EHUMIDISTAT OR
UTOMATIC
HEPA
FILTER OR
MEMBRANE
)
VD0493
F
ILTER