10. MAINTENANCE / INSTRUCTIONS FOR USER
Risk of electric shocks. Before performing any maintenance or servicing, always disconnect the unit from its
power source.
•
Review with the user the steps required for the regular maintenance of her/his ventilation system. These steps are described in detail
in the user manual.
•
Warn the user of the necessity to rebalance the system following a major house renovation or following the installation of any extra
registers.
•
Make sure the user understands how to use the controls as described in the user manual.
Do not oil the motor. It is already permanently lubricated.
!
WARNING
FOUR TIMES A YEAR
•
Inspect the intake hood, and clean if needed.
•
Clean the filters.
•
Clean the interior of the cabinet and clean the door.
•
Clean the condensation tray and inspect the drain tubing.
ONCE A YEAR
•
Clean the heat recovery core.
•
Clean the blades of the blower wheels if needed.
CAUTION
17