Step Nine: Check And Test Completed Assembly - Brave MBRSW1040EA.2 Owner's Manual

Table of Contents

Advertisement

Step 9: Check and test completed assembly.
Serious injury could result from chemical leaks if sprayer is improperly
assembled or the design of the sprayer is modified.
Follow the steps below to ensure the sprayer is properly assembled. Never modify
the sprayer's design.
1. Check assembly
2. Test with water
Assembly
WARNING
Check and test completed assembly
Check assembly to assure the sprayer is properly assembled and in safe
working condition:
a) Check that the gun clip screws are tight, hose clamps are secure, and all
fasteners are tight.
b) While it is unlikely that factory assembled components become loose, they
should also be checked to make sure they are tight.
Test the system for leaks with water:
a) Fill the tank with water.
b) Connect the battery wire harness to the pump power cord and turn the
ON/OFF switch ON. The pump is an "on demand" pump. When turned on,
the pump will prime itself, and then turn off. When the gun trigger is
squeezed, the pump will automatically start.
c) Operate the spray gun by squeezing the gun trigger.
d) Check for leaks throughout the system. If a leak is detected, fix the leak and
re-test the system with water.