Conrad FX-505 C2 Series Instruction Manual

Digital fiber sensor amplifier

Advertisement

Quick Links

Digital Fiber Sensor Amplifier FX-505□-C2
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct and
optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
● Never use this product as a sensing device for personnel protection.
● In case of using sensing devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
INTENDED PRODUCTS FOR CE MARKING
1
● This product complies with the following standards / regulations.
<EU Directive>
EMC Directive 2004/108/EC
<Standards in US / Canada>
ANSI/UL 60947-5-2, CAN/CSA C22.2 No.14
<Regulations in Korea>
S1-G-1-2009, S2-W-5-2009
● Caution about UL recognition
In case requiring conformity of UL listing mark or C-UL listing mark, USe class
2 power supply unit.
2
PART DESCRIPTION
Sensing output 2
UP key
selection indicator
• Teaching
(Yellow)
• Threshold value
Sensing output 1
fine adjustment
selection indicator
• Select setting items
(Yellow)
Sensing output 1
Digital display
operation indicator
(Green / Red)
(Orange)
MODE indicator: L / D (Yellow)
Sensing output 2
MODE indicator: CUST (Yellow)
operation indicator
(Orange)
MODE indicator: PRO (Yellow)
<Reference>
Pressing down SET key + MODE key for 3 sec : Set key lock or Release key lock
3
MOUNTING
How to connect
1. Fit the rear part of the mounting sec-
tion of the amplifier on a DIN rail.
2. Press down the rear part of the
mounting section of the unit on the
DIN rail and fit the front part of the
mounting section to the DIN rail.
How to remove
1. Push the controller forward.
2. Lift up the front part of the amplifier
to remove it.
How to connect the fiber cable
Be sure to fit the attachment to the fibers first before inserting the fibers to the
amplifier. For details, refer to the Instruction Manual enclosed with the fibers.
1. Snap the fiber lock lever down till it
stops completely.
2. Insert the fiber cables slowly into the
inlets until they stops. (Note)
3. Return the fiber lock lever to the
original position till it stops.
Note: With the coaxial reflective type fiber, such as , FD-G4 or FD-FM2, insert the single core fiber cable into the
beam-emitting inlet "P" and the multi-core fiber cable into the beam-receiving inlet.
If they are inserted in reverse, the sensing performance will deteriorate.
INSTRUCTION MANUAL
MJE-FX505C2 No.0015-29V
WARNING
SET key
DOWN key
• Teaching
• Teaching
• C o n f i r m s e t t i n g
• Threshold value fine
contents
adjustment
• Select setting items
MODE key
• Select Modes
• Cancel during setting
• Select sensing output 1/2
by pressing long
2. Press down
35mm width DIN rail
1. Push forward
2. Lift up
3. Return
1. Snap
Fiber lock lever
Fiber for emitter
2. Insert
Fiber for
receiver
4
I/O CIRCUIT DIAGRAMS
<FX-505-C2>
<FX-505P-C2>
Note: Make sure to insulate the ends of the unused lead wires.
5
OPERATION PROCEDURE
● The sensing output can be switched to sensing output 1 or sensing output 2
by holding down the mode key.
● The changed settings are not stored if turning the power OFF while setting.
Therefore, confirm the settings by pressing the SET key before turning the
power OFF.
● When turning ON the power, RUN mode is displayed and the digital display
shows the threshold value (green) and the incident light intensity (red).
<RUN mode>
<Sensing output operation mode>
<CUSTOM mode>
<PRO mode>
1. Fit
<RUN mode>
(Brown) +V
Load
(Pink) External input
Load
(Black) Sensing output 1
(White) Sensing output 2
(Blue) 0V
(Gray) Monitor current output (4 to 20mA)
(Brown) +V
(Black) Sensing output 1
(White) Sensing output 2
Load
(Pink) External input
Load
(Blue) 0V
(Gray) Monitor current output (4 to 20mA)
• Displays threshold value (green) and incident light intensity (red).
• Teaching, threshold value fine adjustment and key lock function
can be set.
• For setting method of each function, refer to "
MODE," "
THRESHOLD VALUE FINE ADJUSTMENT FUNC-
TION," or "
KEY LOCK FUNCTION."
• Select either Light-ON or Dark-ON.
• For the setting, refer to "
SENSING OUTPUT OPERATION
MODE."
• The default setting is "
" (Light-ON).
• An item set in CUSTOM mode (Response time setting, Emission
power setting and Hysteresis setting) is displayed.
• For details, refer to "
CUSTOM MODE."
• The default setting is "
" (response time setting).
• Advanced setting can be done.
PRO MODE."
• For the setting, refer to "
+
12 to 24V DC
%
-
Load (0 to 250Ω)
+
12 to 24V DC
%
-
Load (0 to 250Ω)
TEACHING

Advertisement

loading

Summary of Contents for Conrad FX-505 C2 Series

  • Page 1 I/O CIRCUIT DIAGRAMS INSTRUCTION MANUAL <FX-505-C2> Digital Fiber Sensor Amplifier FX-505□-C2 (Brown) +V MJE-FX505C2 No.0015-29V Load (Pink) External input Load (Black) Sensing output 1 Thank you very much for purchasing Panasonic products. 12 to 24V DC Please read this Instruction Manual carefully and thoroughly for the correct and (White) Sensing output 2 optimum use of this product.
  • Page 2 TEACHING MODE 1-point teaching [Window comparator mode (except sensing output 2) / Hysteresis mode] ● Be sure that detection may become unstable depending on the use environ- ● This is method to set the shift amount to the desired value and to set the ment in teaching if less margin is applied.
  • Page 3 THRESHOLD VALUE FINE ADJUSTMENT FUNCTION PRO MODE ● Set fine adjustment of threshold value in RUN mode. ● When MODE indicator: PRO (yellow) lights up, PRO mode can be set. ● Also, the threshold value fine adjustment function can be used in forced ON ●...
  • Page 4 OPTICAL COMMUNICATION ERROR INDICATION ● When the setting of data bank loading / saving, copy setting, or copy action ● In case of errors, attempt the following measures. setting is conducted via optical communications, cascade the sub amplifiers Error Description Remedy right side to the main amplifier as follows.