9
|
Electrical installation

9.3.5 To connect the domestic hot water pump

Installer reference guide
118
B
A
B
3 Fix the cable with cable ties to the cable tie mountings.
Wires: (2+GND)×0.75 mm²
DHW pump output. Maximum load: 2 A (inrush), 230 V AC, 1 A
(continuous)
[9.2.2] DHW pump
[9.2.3] DHW pump schedule
1 Open the following (see
1 Top panel
2 User interface panel
3 Upper switch box cover
2 Connect the domestic hot water pump cable to the appropriate terminals as
shown in the illustration below.
A
3 4 5 6
X5M
"7.2.5 To open the indoor
M M2P
1~
EPRA08~12EAV3+W1 + ETVH/X12S18+23EA6V+9W
4
unit" [
 68]):
1
3
2
Daikin Altherma 3 H MT F