4
|
Operation
4.4.2 To turn ON or OFF
User reference guide
30
Room temperature control
1 Go to [C.1]: Operation > Room.
C.1
Operation
Room
Space heating/cooling
2 Set operation to On or Off.
Space heating/cooling operation
NOTICE
Room frost protection. Even if you turn OFF space heating/cooling operation ([C.2]:
Operation > Space heating/cooling), room frost protection –if enabled– will
remain active.
NOTICE
Water pipe freeze prevention. Even if you turn OFF space heating/cooling operation
([C.2]: Operation > Space heating/cooling), water pipe freeze prevention –if
enabled– will remain active.
1 Go to [C.2]: Operation > Space heating/cooling.
C.2
Operation
Room
Space heating/cooling
Tank
2 Set operation to On or Off.
Tank heating operation
NOTICE
Disinfection mode. Even if you turn OFF tank heating operation ([C.3]: Operation >
Tank), disinfection mode will remain active. However, if you turn it OFF while
disinfection is running, an AH error occurs.
1 Go to [C.3]: Operation > Tank.
C.3
Operation
Space heating/cooling
Tank
2 Set operation to On or Off.
On
On
On
On
Off
On
Off
ETVZ16S18+23DA6V+9W
Daikin Altherma 3 H HT F
4P586461-1A – 2020.01