Midi Implementation; Thru'ed Data; Control Data Transmission - Roland VE-7000 Owner's Manual

Ch edit controller
Table of Contents

Advertisement

MIDI Implementation

1. THRU'ed data

All data received at MIDI IN will be transmitted from MIDI OUT. This is
called "Thru." The data that is "thru'ed" will be mixed with the output data
of the VE-7000 itself, and sent from MIDI OUT. For this reason, status bytes
that were abbreviated by running status from the data received via MIDI
will be added as necessary.

2. Control data transmission

When you operate the panel buttons, dials, or joystick, the following
exclusive messages will be transmitted.
Status
Data bytes
F0H
41H,7FH,00H,36H,12H,adh,adm,adl,dat,sum
Byte
Description
F0H
Status of System Exclusive Message
41H
Manufacturer ID (Roland)
7FH
Device ID
00H 36H
Model ID (VE-7000)
12H
Command ID (DT1)
adh
Address MSB
adm
Address MID
adl
Address LSB
dat
Data
sum
Checksum
F7H
EOX (End of Exclusive)
DEVICE ID
The device ID is used to distinguish between devices, in a way similar to
MIDI channels. On the VE-7000, this is fixed at 7FH. This is the "broadcast"
device ID, and its messages will apply to all connected devices.
MODEL ID
The model ID of the VE-7000 is 00H 36H.