STEP 3:
PREPARE THE VENTING BLOWER
Your microwave oven is shipped with the blower assembled for room venting (recirculating). You need to adjust
the blower if you want wall vented or roof vented installation.
ELECTRICAL SHOCK HAZARD! UNPLUG UNIT BEFORE WORKING ON IT.
G
DO NOT PULL OR STRETCH THE BLOWER WIRING! Pulling and stretching the blower wiring could result
in electrical shock.
REMOVE THE MOUNTING PLATE:
1. Remove any shipping materials and parts from inside
the microwave oven.
2. Cover the counter top or cooktop with a thick,
protective covering to protect it from damage and dirt.
See Figure 10.
NOTE: If you have a free-standing range, disconnect
it, move it onto a piece of cardboard or
hardboard and pull it away from the wall, so
that you can get closer to the upper cabinet
and back wall for easier measuring and
drilling.
3. Remove mounting plate 2 screws from the mounting
plate as shown and discard them.
(See Figure 11.)
4. The mounting plate will also be used to locate and
mark the mounting holes on the rear wall.
5. Locate exhaust adaptor, grease filters and hardware
packet.
6. At this point, remove any adhesive tape (if there is
any), on the exhaust adaptor, the grease filters and
the power supply cord.
ROOM VENTED INSTALLATION:
Go to STEP 4, PREPARE THE WALL AND UPPER
CABINET FOR INSTALLATION located on page 13.