Page 3
There are no user or operator serviceable parts within the product enclosure. Refer all servicing to qualified and trained Kepco service technicians. 228-1351 COND/CONFORM 101718...
Page 4
SAFETY INSTRUCTIONS 1. Installation, Operation and Service Precautions This product is designed for use in accordance with EN 61010-1 and UL 3101 for Installation Category 2, Pollution Degree 2. Hazardous voltages are present within this product during normal operation. The prod- uct should never be operated with the cover removed unless equivalent protection of the operator from accidental contact with hazardous internal voltages is provided: There are no operator serviceable parts or adjustments within the product enclosure.
TABLE OF CONTENTS SECTION PAGE SECTION 1 - INTRODUCTION Scope Of Manual............................. 1-1 General Description..........................1-1 Specifications, Electrical.......................... 1-3 DC Output Ratings For 1/3, 2/3 And Full Rack Modules ................. 1-4 Miscellaneous Features .......................... 1-8 Accessories ............................. 1-8 Safety ..............................1-9 SECTION 2 - INSTALLATION Unpacking And Inspection........................
Page 6
FIGURE TITLE PAGE Remotely Controlled Power Supply Configurations Using Kepco Products..........1-2 MAT Power Module Mechanical Outline Drawing ..................1-6 The TMA 4882-27 Controller And MAT Power Modules ................1-9 Front View Of The Full Rack MAT Power Supply ..................2-2 Rear View Of The MAT Full Rack Power Module ..................
Page 7
LIST OF TABLES TABLE TITLE PAGE MAT Power Module Features And Specifications ..................1-3 MAT Power Modules Power Output Ratings ....................1-5 Safety Symbols ............................1-9 Internal Controls Accessible Through Top Cover ..................2-1 Front Control MAT Power Module ......................2-2 Rear Terminations, MAT Power Module .....................2-3 DC Output Connector Pin Functions ......................2-3 Input And Output Connectors ........................2-4 Internal Jumper Configuration ........................2-9...
NPN pass transistor driven by high gain integrated circuit amplifiers. The output of the Power Module is fully programmable The Power Module features full range output control by means of a compatible Kepco Power Module Controller. Control of the MAT Power Module is via the IEEE 1118 2-wire serial bus operating at 375KHz;...
Leakage Current Output to chassis A rms or 50 A p-p @ 115V a-c Series/Parallel Operation Consult Kepco application engineering 3-1/2 digit LCD Output Display Switch selectable voltage/current Panel Meter Voltage and Current Mode,Output Enabled, Polarity IndIcators 4 LEDs...
TABLE 1-1. MAT POWER MODULE FEATURES AND SPECIFICATIONS (CONTINUED) MAT POWER MODULE PARAMETER CONDITION 1/3 RACK 2/3 RACK FULL RACK Overvoltage Tracks program voltage, Crowbars output and turns off input Overcurrent Tracks program current, Crowbars output and turns off input Monitors heat sink temperature, Crowbars output and turns Protection Overtemperature...
Page 13
MAT 55-14 0-55 0-14 MAT 75-10 0-75 0-10 MAT 100-7.2 0-100 0-7.2 MAT 150-4.8 0-150 0-150 1080W MODULES-FULL RACK-DC OUTPUT RATINGS MAT 6-100 0-100 MAT 15-60 0-15 0-60 MAT 25-42 0-25 0-42 1050 MAT 36-30 0-36 0-30 1080 MAT 55-20...
Page 14
FIGURE 1-2. MAT POWER MODULE MECHANICAL OUTLINE DRAWING (SHEET 1 OF 2) MAT FULL RACK 101718...
Page 15
FIGURE 1-2. MAT POWER MODULE MECHANICAL OUTLINE DRAWING (SHEET 2 OF 2) MAT FULL RACK 101718...
One 2 meter long shielded twisted pair cable with two DIN mating connectors (see Table 2- 5), one at each end (Kepco P/N 118-0699) is supplied with each Rack Adapter (RA 50 or RA 51) and with each Full Rack MAT Power Module. The Power Module Controller (see PAR.
There are no operator serviceable parts inside the case. Service must be referred to authorized personnel. Using the power supply in a manner not specified by Kepco. Inc. may impair the pro- tection provided by the power supply. Observe all safety precautions noted throughout this man- ual.
SECTION 2 - INSTALLATION UNPACKING AND INSPECTION This instrument has been thoroughly inspected and tested prior to packing and is ready for operation. After careful unpacking, inspect for shipping damage before attempting to operate. Perform the preliminary operational check as outlined in PAR 2.8 If any indication of damage is found, file an immediate claim with the responsible transport service.
Page 20
TABLE 2-2. FRONT CONTROL MAT POWER MODULE ITEM NO. CONTROL FUNCTION (See Fig. 2-1) AC POWER Switch/circuit Breaker Serves as an AC power switch and turns the AC power line off on overvoltage, overcurrent, overtemperature or power loss. CAUTION: DO NOT repeatedly toggle the circuit breaker/switch as this may cause unit to fault.
TABLE 2-3. REAR TERMINATIONS, MAT POWER MODULE ITEM NO. REAR TERMINATION FUNCTION (See Fig. 2-2) DC OUTPUT Connects the MAT power module output lines, sensing lines and ground line to CONNECTOR the load (connector supplied). Refer to figure 2-2 for pin designations. Connects MAT power module to the IEEE 1118 control bus.
TABLE 2-5. INPUT AND OUTPUT CONNECTORS CHASSIS MOUNT MATING PLUG AC INPUT CONNECTOR (MIL STD CONNECTOR, MS TYPE OR EQUIVALENT) MS3108A16--10S MS3102A16-10P (KEPCO P/N 143-0331) DC OUTPUT CONNECTORS (MIL STD CONNECTOR, MS TYPE OR EQUIVALENT) MS3106A28-5P M3102A28-5S (KEPCO P/N 142-0358) DIGITAL BUS CONNECTOR...
National and international safety standards set procedures for the grounding of a metal cover and chassis of an instrument connected to an ac power source. The MAT Power Module is supplied with an ac female plug (MS3106A16-10S, Kepco P/N 143- 0331), that mates with a chassis mounted male receptacle (MS3102A16-10P. Kepco P/N 142- 0268).
WARNING Keep the Power Module grounded when connected to an AC power source. 2.6.2 DC (OUTPUT) GROUNDING DC output connections are those between the Power Module and the load, including remote sensing connections if necessary. Despite precautions to eliminate noise such as shielding and twisted wire-pairs, output connections may pick up radiated noise of a wide frequency.
FIGURE 2-4. VARIATION OF OUTPUT IMPEDANCE WITH FREQUENCY FOR A VOLTAGE SOURCE AND A CURRENT SOURCE A practical model for a voltage stabilized Power Module includes a series inductance represent- ing dc and low frequency source impedance. Load leads should have minimum voltage drops (error sensing is discussed below) and minimum inductance (error sensing does not compen- sate for this).
2.6.4 LOAD CONNECTION, LOCAL ERROR SENSING The DC OUTPUT connector is located on the back of chassis, and is designated A6-J2 in the schematic. Table 2-4 and Figure 2-2 provide the function and location of DC OUTPUT connector pins. NOTE: The sense terminals MUST be configured for either local sensing (as follows) or remote sensing (see PAR.
In this procedure the MAT Power Module Control Bus address is 3, (it is set at the factory to 3). Connect the Kepco Power Module Controller and the MAT Power Module (following check-out uses a MAT Power Module Model 100-10 as an example) to the Control Bus. Connect the Host Computer and the Power Module Controller to the IEEE 488 GPIB.
Device Clear Interface Function via the Host Computer. For proper time delays between com- mands refer to PAR. 3.4. For details on the CIIL commands refer to PAR. 3.6.3 and Appendix C as well as the Power Module Controller Manual. The following does not include the IEEE 488 Bus Commands.
The MAT previously set up now starts to measure and send the proper time delay needed for the measurement. The Power Module Controller will send the time delay value back to the Host Computer when it has been properly Talk Addressed (see specific IEEE 488 interface require- ments): 00(cr)(lf) 10.
The MAT previously set up now starts to measure and send the proper time delay needed for the measurement. The Power Module Controller will send the time delay value back to the Host Computer when it has been properly Talk Addressed (see specific IEEE 488 interface require- ments): 00(cr)(lf) The Host Computer then sends:...
(see Figures 3-1 and 3-2 and Table 3-1). This address is set at Kepco to 3. The MAT family of Power Modules is controlled by the Power Module Controller (see PAR. 1.2).
Page 32
TABLE 3-1. DEVICE ADDRESS SELECTION FOR THE MAT POWER MODULE DECIMAL A3S1-4 A3S1-3 A3S1-2 A3S1-1 A3S1-0 ADDRESS (A4) (A3) (A2) (A1) (A0) MAT FULL RACK/ 101718...
Power for the microcomputer board of the TMA 4882-27 Power Module Controller is provided by a wide range input Power Supply, Kepco Model MRW 150KV. The AC input voltage can range from 95 Volts AC to 264 Volts AC, thereby eliminating the need for an input voltage selector.
command causes noncatastrophic error messages to be stacked in memory until interrogated by a Status command. AUTOMATIC (TRACKING) CONTROL OF THE CROWBAR LEVEL MAT Power Modules have Overvoltage and Overcurrent Tracking Amplifiers. These amplifiers will cause a crowbar flag, send a catastrophic error to the Power Module Controller and shut the module down if the output goes out of tolerance.
REMOTE PROGRAMMING 3.6.1 GENERAL Kepco MAT Power Supplies are programmed over a control bus using either SCPI (Standard Commands for Programmable Instruments) or CIIL (Control Interface Intermediate Language) commands. SCPI and CIIL provide a common language conforming to IEEE488.2 for instru- ments used in an automatic test system.
For the complete command set, and detailed SCPI programming information, consult the Technical Manual for the applicable controller (the SCPI command sets among Kepco con- trollers are slightly different). See PAR.3.2 to establish the MAT power supply Control Bus (BIT- BUS) address.
Page 37
/**************************************************************************/ Sample Program For KEPCO power supply, using National Instruments GPIB interface card and IBM PC or compatible computer /**************************************************************************/ #include <stdio.h> #include "decl.h" char rd_str[80]; // Input buffer char dat_str[80]; // Output buffer bd,adr; main() { adr = ibfind("DEV6");...
3.6.3 CIIL PROGRAMMING The CIIL command language is used on early models of Kepco power supplies and controllers. The command functions are included here for compatibility with other equipment programmed with CIIL commands. The CIIL command set for the MAT Power Supply is defined and explained in Appendix C.
Page 39
2. To verify the previous command was implemented the Host Computer sends: STA(cr)(lf) The Power Module Controller sends back (if no errors occur) (sp)(cr)(lf) 3. To close the Output Enable relay (connects the Power Module to the load) the Host Com- puter sends: :CH9(sp)(lf) The Power Module at address 9, closes the relay...
8. To open the Output Enable relay (disconnect the load from the Power Module), the Host Computer sends: :CH9(cr)(lf) The Power Module relay at address 9 is open 9. To verify the previous command was implemented, the Host Computer sends: STA(cr)(lf) The Power Module Controller sends back (if no errors occur) (sp)(cr)(lf)
6. To take reading the Host Computer sends: VOLT(cr)(lf) The MAT previously set up now starts to measure and sends the proper time delay needed for the measurement The Power Module Controller will send the time delay back to the Host Computer when it has been Talk Addressed (see specific IEEE 488 interface requirements): 00(cr)(lf) 7.
3. To enable the output, the Host Computer sends: :CH9(cr)(lf) 4. To verify the previous command was implemented the Host Computer sends: STA(cr)(lf) The Power Module Controller sends back (if no errors occur): (sp)(cr)(lf) 5. To measure the current at the output the Host Computer sends: CURR :CH9(cr)(lf) The MAT at address 9 is now set to take a reading...
NOTE: E and I must be replaced with numerical values that represent the maximum o max o max output voltage (E ) and maximum output current (I ) respectively of the unit o max o max under test. For example, for a MAT 100-10 unit E = 100 Vdc and I = 10 A.
Page 44
7. Send the following commands to set current to 0 and voltage limit to E o max SCPI COMMANDS CIIL COMMANDS FUNC1:MODE CURR FNC DCS :CH1 SET CURR 0 SET VLTL E o max VOLT1 E o max ; CURR1 0; 8.
3.7.2 E/I FULL SCALE CALIBRATION The following procedure requires that E/I zero calibration (PAR. 3.7.1) be performed first. 1. Connect a precision Digital Voltmeter to the rear output Connector Error Sensing termi- nals (see Figure 3-2 and Table 3-2). At this time the load should be disconnected and the Error Sensing terminals should be connected to the corresponding power output ter- minals.
Page 46
10. Adjust R16 until the measured output current by the external ammeter is omax ----------------- - omax 2x4095 11. Disable the output by sending Reset command SCPI COMMANDS CIIL COMMANDS *RST 12. Disconnect the Digital Ammeter and the Digital voltmeter. 3-16 MAT FULL RACK/ 101718...
APPENDIX A - CIIL COMMAND DEFINITIONS INTRODUCTION This appendix defines the CIIL commands used with the MAT Power Supply. Table C-1 provides a quick reference of all CIIL commands used in the MAT Power Supply. TABLE A-1. CIIL SUBSYSTEM COMMAND/QUERY INDEX COMMAND PAGE COMMAND...
Syntax: INX VOLT (initiate voltage reading) INX CURR (initiate current reading) Function: Commences a data acquisition process in accordance with the preceding FNC command. Description: The response to the INX command is a dynamic time-out value, unless a catastrophic error condition exists, in which case an error message will be returned.
VOLT or CURR value so that the power supply's polarity may be selected. In the case of Kepco's MAT power supplies, the two related Op Codes, SRX and SRN are functionally identical to the SET command, since there is only one range, 0 - maximum. The commands are included only for compatibility.
OPN, CLS Syntax: OPN :CHnn CLS :CHnn Function: These commands are used to connect or disconnect the power supply from the load (effective for MR and MGR options only). Description: Disconnects the load from the power supply specified by the operand. Connects the load to the power supply specified by the operand.
Page 51
Syntax: Function: Causes power supply to return operating status to controller. Description: This operator commands the power supply to report its present operating status. Status is reported in the form of a message (character string) as defined below. Any catastrophic error conditions (indicated by * in the table below) which exist will be reported, until the error condition is corrected.