Siemens 19T2 Service Manual page 21

Color monitor
Hide thumbs Also See for 19T2:
Table of Contents

Advertisement

Connect the communication cable of the computer to the connector located on the D board on the monitor. Run the service software
and then follow the instruction.
IBM AT Computer
as a Jig
• Convergence Rough Adjustment
(1) Receive an image of the white crosshatch signals (white
lines on black).
(2) Make rough adjustment of the H and V direction conver-
gence by using 4-fold poles magnet.
(3) Make rough adjustment of the HMC and VMC by using 6-
fold poles magnet.
<"0" position of each magnet and TLH plate>
a) Align the protrusion marked with an arrow.
[4-fold poles magnet]
[2-fold poles
magnet on the DY]
[6-fold poles magnet] [2-fold poles magnet
on neck assy]
b) Flush the shaded portions of TLH plate with the DY rear
cover, as shown below.
[Rear view]
or
[Movements of TLH plate]
or
[Movements of XCV volume]
www.rtv-horvat-dj.hr
All manuals and user guides at all-guidesbox.com
1
1-690-391-21
2
A-1500-819-A
Interface Unit
D-sub
mini Din
(9 Pin [female])
(8Pin)
*The parts above (
) are necessary for DAS adjustment.
1
3
TLV
TLH
plate
XCV
TLH plate
DY rear cover
2-fold poles magnet
4-fold poles magnet
6-fold poles magnet
3
3-702-691-01
Connector Attachment
To BUS CONNECTOR
4 Pin
4 Pin
4 Pin
• Convergence Specification
A
V
• White Balance Adjustment Specification
1. 9300 K
x = 0.283 ± 0.015
y = 0.298 ± 0.015
(All White)
2. 5000 K
x = 0.346 ± 0.015
y = 0.359 ± 0.015
(All White)
• Vertical and Horizontal Position and Size
Specification
A
b
b
a
a
2.0 mm
b
2.0 mm
• Focus adjustment
Adjust the focus volume 1 and 2 for the optimum focus.
FBT ASSY
4-2
B
All mode
MODE
0.20 mm
A
0.24 mm
B
All mode
MODE
B
A
352 mm
a
B
264 mm
FOCUS 1
FOCUS 2
19T2

Advertisement

Table of Contents
loading

Table of Contents