Advertisement

WFIN-26110 / WFOD-26111
WFIN-35110 / WFOD-35111
WFIN-50110 / WFOD-50111
WFIN-70110 / WFOD-70111

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WFIN-26110 and is the answer not in the manual?

Questions and answers

Summary of Contents for Morris WFIN-26110

  • Page 1 • WFIN-26110 / WFOD-26111 • WFIN-35110 / WFOD-35111 • WFIN-50110 / WFOD-50111 • WFIN-70110 / WFOD-70111...
  • Page 6 ON / OFF Emergency button Emergency button display PCB front panel ON/OFF front panel ON/OFF...
  • Page 7 CLOCK DISPLAY HEALTHY ON/OFF SWING TIMER SUPER SLEEP MODE FEEL SPEED AUTOQUIET COOL POWERFUL SWING DELAY HEAT HEALTHY TIMER ON/OFF MODE TIMER ANTI-MILDEW FAN SPEED SUPER SWING SLEEP HEALTHY DISPLAY RESET MODE TIMER SLEEP DISPLAY SWING SWING HEALTHY TURBO Feel Cool Heat Timer Timer...
  • Page 8 HEALTHY TIMER FEEL SPEED AUTOQUIET COOL POWERFUL SWING DELAY HEAT HEALTHY TIMER TIMER TIMER AUTO or (FLASH) QUIET or Feel Cool Dry Heat Timer Timer Auto Low Mid High Sleep Swing TURBO POWERFUL HEALTHY SLEEP TIMER ON TMIER OFF AUTO FEEL HIGH COOL...
  • Page 9 FEEL FEEL SPEED SPEED COOL COOL SWING SWING HEAT HEAT HEALTHY HEALTHY TIMER TIMER Signal receptor Remote controller holder...
  • Page 10 FEEL SPEED AUTOQUIET COOL POWERFUL SWING DELAY HEAT SWING HEALTHY TIMER SWING ON/OFF MODE TIMER ANTI-MILDEW HEALTHY TIMER FAN SPEED SUPER SWING SLEEP HEALTHY...
  • Page 11 COOL COOL FEEL SPEED AUTOQUIET COOL POWERFUL SWING DELAY HEAT HEALTHY TIMER ON/OFF HEALTHY MODE TIMER ANTI-MILDEW TIMER FAN SPEED SUPER SWING SLEEP HEALTHY HEAT HEAT FEEL SPEED AUTOQUIET COOL POWERFUL SWING DELAY HEAT HEALTHY TIMER ON/OFF MODE TIMER ANTI-MILDEW HEALTHY TIMER FAN SPEED...
  • Page 12 TIMER FEEL SPEED AUTOQUIET COOL TIMER POWERFUL SWING DELAY HEAT HEALTHY TIMER ON/OFF MODE TIMER ANTI-MILDEW FAN SPEED SUPER SWING SLEEP HEALTHY POWER SLEEP TIMER FEEL SPEED AUTOQUIET COOL POWERFUL SWING DELAY HEAT HEALTHY TIMER TIMER ON/OFF TIMER MODE TIMER ANTI-MILDEW FAN SPEED SUPER...
  • Page 13 FEEL SPEED AUTOQUIET COOL POWERFUL SWING DELAY HEAT HEALTHY TIMER ON/OFF HEALTHY MODE TIMER ANTI-MILDEW TIMER FAN SPEED SUPER SWING SLEEP HEALTHY FEEL SPEED AUTOQUIET COOL POWERFUL SWING DELAY HEAT HEALTHY TIMER ON/OFF MODE TIMER ANTI-MILDEW HEALTHY TIMER FAN SPEED SUPER SWING SLEEP...
  • Page 14 FEEL FEEL SPEED AUTOQUIET COOL FEEL POWERFUL SWING DELAY HEAT HEALTHY TIMER ON/OFF HEALTHY TIMER MODE TIMER ANTI-MILDEW FAN SPEED SUPER SWING SLEEP HEALTHY AUTO QUIET AUTOQUIET FEEL SPEED AUTOQUIET COOL POWERFUL SWING DELAY HEAT HEALTHY TIMER ON/OFF MODE TIMER ANTI-MILDEW HEALTHY TIMER...
  • Page 17 don't run...
  • Page 21 wrapped with vinyl type Thermal insulation Large pipe Thermal insulation tube Power cord Small pipe Power cord 1 (for heat-pump) Drain hose Defrost cable(for heat-pump) (prepared by user)
  • Page 22 28/30k 22/24k 15/18k ( 6 ) ( 6 ) ( 6 ) ( 6 ) ( 6 ) ( 9.52) ( 9.52) ( 9.52) ( 9.52) ( 9.52) ( 12) ( 12) ( 15.88) ( 15.88) 20g/m 20g/m 20g/m 20g/m 30g/m 30g/m 30g/m...
  • Page 23 Front panel Terminal (inside) Cabinet Indoor unit Chassis Access door Terminal(inside) Outdoor unit...
  • Page 24 22/24k 28/30k 15/18k 1.0mm 2.5mm 1.0mm 1.0mm 1.0mm 1.5mm 4.0mm (1.5mm) AWG14 AWG12 AWG18 AWG18 AWG18 AWG18 AWG16 H05RN-F (AWG16) 1.0mm 2.5mm 1.0mm 1.0mm 1.0mm 1.5mm 4.0mm (1.5mm) AWG14 AWG12 AWG18 AWG18 AWG18 AWG16 AWG18 H05RN-F (AWG16) 1.0mm 2.5mm 1.0mm 1.0mm 1.0mm (1.5mm)
  • Page 25 Washer Drain port Drain hose (prepare by user)
  • Page 27: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ....................1 .........................4 NAMES OF PARTS INDOOR UNIT DISPLAY ......................5 EMERGENCY FUNCTION & AUTO-RESTART FUNCTION ..........6 REMOTE CONTROLLER ......................7 OPERATING INSTRUCTIONS .....................10 .........................15 PROTECTION INSTALLATION MANUAL ....................16 MAINTENANCE ........................25 ......................26 TROUBLESHOOTING...
  • Page 28 SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER Do not install the appliance at a distance of Read this guide before installing and using the less than 50 cm from inflammable substances appliance. (alcohol, etc.) Or from pressurised containers (e.g. spray cans). During the installation of the indoor and outd- oor units the access to the working area should If the appliance is used in areas without the...
  • Page 29 SAFETY RULES AND RECOMMENDATIONS FOR THE USER Do not try to install the conditioner alone; Never remain directly exposed to the flow of always contact specialized technical personnel. cold air for a long time. The direct and prolo- nged exposition to cold air could be dangero- Cleaning and maintenance must be carried out us for your health .Particular care should be by specialised technical personnel.
  • Page 30 SAFETY RULES AND PROHIBITIONS Do not bend , tug or compress the power cord Do not climb onto or place any heavy or hot since this could damage it. Electrical shocks or objects on top of the appliance. fire are probably due to a damaged power cord. Do not leave windows or doors open for long Specialised technical personnel only must repl- when the air conditioner is operating.
  • Page 31: Names Of Parts

    NAMES OF PARTS INDOOR UNIT INDOOR UNIT Description Front panel Air filter Optional filter (if installed) LED Display Signal receiver Terminal block cover Ionizer generator (if installed) Deflectors Emergency button Indoor unit rating label ( Stick position optional Airflow direction louver Remote controller OUTDOOR UNIT No.
  • Page 32: Indoor Unit Display

    INDOOR UNIT DISPLAY Function This symbol appears when the unit is power on POWER SLEEP mode SLEEP (1) Lights up during Timer operation when the air conditioner is operational Temperature display (if present) (2)Displays the malfunction code when fault /Error code occurs.
  • Page 33: Emergency Function & Auto-Restart Function

    EMERGENCY FUNCTION & AUTO-RESTART FUNCTION AUTO-RESTART FUNCTION The appliance is preset auto - restart function by manufacturer. In case of a sudden power failure, the ON / OFF module memorizes the setting conditions before the power failure. when the power restores, the unit restarts automatically with all the previous settings preserved by the memory function.
  • Page 34: Remote Controller

    REMOTE CONTROLLER Button Function (TEMP UP) Press it to increase temperature / time setting. (TEMP DN) Press it to decrease temperature/ time setting. DISPLAY HEALTHY CLOCK ON/OFF Press it to start or stop operation. ON/OFF SWING To select the fan speed of auto/low/mid/high TIMER SUPER SLEEP...
  • Page 35 REMOTE CONTROLLER Remote controller DISPLAY Meaning of symbols on the liquid crystal display Meaning Symbols HEALTHY TIMER FEEL mode indicator COOLING indicator DEHUMIDIFYING indicator FEEL SPEED AUTOQUIET FAN ONLY OPERATION indicator COOL POWERFUL SWING DELAY HEAT HEATING indicator HEALTHY TIMER SIGNAL RECEPTION indicator TIMER OFF indicator TIMER...
  • Page 36 REMOTE CONTROLLER Replacement of Batteries Remove the battery cover plate from the rear of the remote controller, by sliding it in the direction of the arrow. nstall the batteries according the direction (+and -)shown on the Remote Controller. Reinstall the battery cover by sliding it into place. Use 2 LRO 3 AAA (1.5V) batteries .
  • Page 37: Operating Instructions

    OPERATING INSTRUCTIONS The air sucked by the fan enters from the grill and passes through the filter, then it is cooled/dehumidified Filter or heated through the heat exchanger. Heat Exchanger The direction of the air outlet is motorized up and down by flaps, and manually moved right and left by the vertical deflectors, for some models, the vertical deflectors could be controlled by motor as well.
  • Page 38 OPERATING INSTRUCTIONS COOLING MODE COOL The cooling function allows the air condit- FEEL COOL SPEED AUTOQUIET COOL ioner to cool the room and at the same time POWERFUL reduces Air humidity. SWING DELAY HEAT To activate the cooling function ( COOL ) , press the HEALTHY TIMER MODE button until the symbol...
  • Page 39 OPERATING INSTRUCTIONS TIMER MODE----TIMER ON TIMER To set the time of the air conditioner FEEL SPEED AUTOQUIET COOL POWERFUL TIMER SWING DELAY To program the automatical switching-on time, the HEAT HEALTHY TIMER appliance should be power off. Press TIMER at the fist time , set the temperature with pressing the button Press TIMER at the second time , set the rest time with ON/OFF...
  • Page 40 OPERATING INSTRUCTIONS FAN MODE The conditioner works in only FEEL SPEED AUTOQUIET COOL ventilation. POWERFUL SWING DELAY HEAT To set the FAN mode , Press MODE untill HEALTHY TIMER ( FAN ) appears in the display. Whith pressing button the speed changes ON/OFF in the following sequence: LOW/ MEDIUM/HIGH /AUTO in FAN mode.
  • Page 41 OPERATING INSTRUCTIONS I FEEL MODE FEEL Automatic mode. I FEEL FEEL SPEED AUTOQUIET COOL POWERFUL SWING DELAY To activate the I FEEL (automatic) mode of operation, HEAT HEALTHY TIMER press the MODE button on the remote controller until the symbol ( I FELL ) appears on the display.
  • Page 42: Protection

    PROTECTION The air conditioner is programmed for comfortable and suitable living conditions, if it is used in abnormal conditioner as below, certain safety protection features might come into effect. For T1 Climate condition models: Ambient temperature MODE Outdoor temperature is over 24 Outdoor temperature is below -7 Heating Room temperature is over 27...
  • Page 43: Installation Manual

    INSTALLATION MANUAL---Selecting the Installation Place INDOOR UNIT Install the indoor unit on a strong wall that is not subject Mounting plate to vibrations. The in let and outlet ports should not be obstructed:the air should be able to blow all over the room. Do not install the unit near a source of heat , steam,or flammable gas.
  • Page 44 INSTALLATION MANUAL---Installation of the Indoor unit Before starting installation, decide on the position of the indoor and outdoor units, taking into account the minim- um space reserved around the units Do not install your air conditioner in a wet room such as a bathroom or laundry etc The installation site should be 250cm or more above the floor.
  • Page 45 INSTALLATION MANUAL---Installation of the Indoor unit Refrigerant piping connection The piping can be run in the 3 directions indicated by numbers in the picture . When the piping is run in direction 1or3, cut a notch along the groove on the side of the indoor unit with a cutter.
  • Page 46 INSTALLATION MANUAL---Installation of the Indoor unit INSTALLATION OF THE INDOOR UNIT After having connected the pipe according to the instruc- Covered by vinyl tape tions, install the connection cables. Now install the drain refrigerant insulation pipe. After connection,lag the pipe, cables and drain pipe pipe sleeve connection...
  • Page 47 INSTALLATION MANUAL---Installation of the outdoor unit ELECTRICAL CONNECTIONS wiring diagram on the back of the cover 1. Remove the handle on the right side plate of outdoor unit. 2. Connect the power connection cord to the terminal board. Wiring should fit that of indoor unit. 3.
  • Page 48 INSTALLATION MANUAL---Installation of the outdoor unit BLEEDING 3-way valve diagram The air and humidity left inside the refrigerant circulat- ion can cause compressor malfunction. After having co- connect to indoor unit nnected the indoor and outdoor units, bleed the air and humidity from the refrigerant circulation using a va- open position cuum pump.
  • Page 49 INSTALLATION MANUAL---Information for the installer FIXED-SPEED TYPE 22/24k 28/30k/36k 15/18k MODEL capacity (Btu/h) Liquid pipe diameter ( 6) ( 6) ( 6) ( 6) ( 6) ( 9.52) ( 9.52) Gas pipe diameter ( 9.52) ( 9.52) ( 9.52) ( 12) ( 12) ( 15.88) ( 15.88)
  • Page 50 INSTALLATION MANUAL---Information for the installer WIRING DIAGRAM For different models, the wiring diagram may be different. Please refer to the wiring diagrams pasted on the indoor unit and outdoor unit respectively. On indoor unit, the wiring diagram is pasted under the front panel; On outdoor unit, the wiring diagram is pasted on the backside of the outdoor handle cover.
  • Page 51 INSTALLATION MANUAL---Information for the installer CABLE WIRES SPECIFICATION 22/24k 28/30k/36k 15/18k MODEL capacity (Btu/h) sectional area 1.0mm 2.5mm 1.0mm 1.0mm 1.0mm (1.5mm) 1.5mm 4.0mm AWG14 AWG12 AWG18 AWG18 AWG18 AWG18 AWG16 H05RN-F (AWG16) Power supply cable 1.0mm 2.5mm 1.0mm 1.0mm 1.0mm 1.5mm 4.0mm...
  • Page 52: Maintenance

    MAINTENANCE Periodic maintenance is essential for keeping your air conditioner efficient. Before carrying out any maintenance , disconnect the power supply by taking the plug out from the socket. INDOOR UNIT ANTIDUST FILTERS 1. Open the front panel following the direction of the arrow 2.
  • Page 53: Troubleshooting

    TROUBLESHOOTING MALFUNCTION POSSIBLE CAUSES Power failure/plug pulled out Damaged indoor/outdoor unit fan motor Faulty compressor thermomagnetic circuit breaker The appliance does not Faulty protective device or fuses. operate Loose connections or plug pulled out It sometimes stops operating to protect the appliance. Voltage higher or lower than the voltage range Active TIMER-ON function Damaged electronic control board...
  • Page 54 Το προϊόν αυτό συμμορφώνεται με τις απαιτήσεις των παρακάτω οδηγιών: • Την οδηγία 2004/108/ΕΚ σχετικά με την ηλεκτρονική συμβατότητα • Την οδηγία 2006/95/ΕΚ σχετικά με το ηλεκτρολογικό υλικό που προορίζεται να χρησιμοποιηθεί εντός ορισμένων ορίων τάσεως • Την οδηγία 2011/65/ΕΕ για τον περιορισμό της χρήσης ορισμένων επικίνδυνων ουσιών σε ηλεκτρολογικό...

Table of Contents